92
XtrapulsPac – User Guide
Chapter 3 - Reference
Sub Index
2
Description Resolver
Configuration
Data Type
Unsigned16
Object Class
all
Access rw
PDO Mapping
No
Default Value
0
Bit Number Description
0 0
Normal
direction
1 Reverse
direction
Sub Index
3
Description
Resolver Virtual Top Z shift
Data Type
Unsigned16
Object Class
all
Access rw
PDO Mapping
No
Default Value
0
This parameter defines the offset between marker Z of the encoder and the virtual marker Z.
The value is given in encoder increments (4096 increments / revolution).
Sub Index
4
Description
Resolver Virtual Top Z size
Data Type
Unsigned16
Object Class
all
Access rw
PDO Mapping
No
Default Value
0
This parameter defines the width of the virtual marker Z.
The value is given in encoder increments (4096 increments / revolution).
The virtual marker Z is working with polling technique, the width of the virtual marker Z allows increasing the
marker Z size in order to avoid a missing of the marker Z.
The status of the virtual marker Z can be read by object 0x3027.
Sub Index
5
Description
Resolver Pole pairs
reserved for future use
Data Type
Unsigned16
Object Class
all
Access rw
PDO Mapping
No
Default Value
1