188
XtrapulsPac – User Guide
Chapter 3 - Reference
Digital Inputs
Index 0x60FD
Name Digital
Inputs
Object Code
VAR
Data Type
Unsigned32
Object Class
all
Access rw
PDO Mapping
Possible
Default Value
No
bit Function
0
Logic Input Negative Limit Switch Function:
0 running
1
stopped in negative direction with stop on current limit
1
Logic Input Positive Limit Switch Function:
0 running
1
stopped in positive direction with stop on current limit
2
Logic Input HOME
0 -
1
Home switch activated
3
Logic Input INHIBIT
0 -
1
drive is disabled
12
Logic Input RESET
↑
fault
reset
13
Logic Input ENABLE
0
drive is disabled
↑
drive is enabled
14
Logic Input Motor Phasing
↑
start motor phasing
15 1
QuickStop
16
Physical intput
IN1
17
Physical intput
IN2
18
Physical intput
IN3
19
Physical intput
IN4
20
Physical intput
IN5
21
22
23
24
25
26
27
28
29
30
Encoder Virtual Top Z (defined by 0x3127)
31
Resolver Virtual Top Z (defined by 0x3107)