88
XtrapulsPac – User Guide
Chapter 3 - Reference
Dynamic Current Limit Configuration
Index 0x30D2
Name
Dynamic Current Limit Configuration
Description
This object allows defining the effect of Dynamic Current Limit signal.
Data Type
Unsigned16
Object Class
all
Access rw
PDO Mapping
No
Default Value
0
Value bit
description
0
0
normal effect of the Dynamic Current Limit signal:
0
current is limited at 0
0x3FFF
corresponds
to
the maximum current (0x6073)
1
reverse effect of the Dynamic Current Limit signal
0x3FFF current is limited at 0
0
corresponds to the maximum current (0x6073)
1..15 reserved
Current Monitor
Index
0x30D4
Name Current
monitor
Object Code
VAR
Data Type
Integer16
Object Class
all
Access ro
PDO Mapping
Yes
Unit
% of drive max. current (0x6510) (0x3FFF = 100% Imax)
Value Range
-
Default Value
-
3.2.2.5 - Motor temperature probe
Index 0x3324
Name
Motor temperature probe configuration
Object Code
RECORD
Object Class
all
Number of Elements
3
This object defines the Motor temperature probe configuration.
Value Description
Sub Index
1
Description
Motor temperature type
Data Type
Integer16
Access rw
PDO Mapping
No
Value -1
NTC
probe
1 PTC
probe
0 No
probe