114
XtrapulsPac – User Guide
Chapter 3 - Reference
This parameter defines the auto-tuning filter:
Value Filter
0 Standard
filter
1 Anti-resonance
filter
2
High stiffness filter
Sub Index
3
Description Speed
Filter
Data Type
Unsigned16
Object Class
-
Access rw
PDO Mapping
No
Value Range
0..2
Default Value
This parameter defines the speed filter:
Value Filter
0 auto-select
by
auto-tuning
1 0.5
ms
2 1
ms
3 2
ms
Sub Index
4
Description
Auto-tuning Application Requirements
Data Type
Unsigned16
Object Class
-
Access rw
PDO Mapping
No
Value Range
0..1
Default Value
Value
Application Requirements
0
Minimum tracking error
1 Minimum
overshoot
Auto-tuning Procedure
Index 0x3426
Name
Start Auto-tuning procedure
Object Code
Data Type
Unsigned32
Object Class
all
Access rw
PDO Mapping
No
Parameters for Auto-tuning (0x3425) must be previously set.
In order to avoid running the auto-tuning procedure by mistake, the auto-tuning is only executed when a specific
signature is written to this sub-index. The signature is 'atun'.
Signature = 0x6E757461
Writing 0 to this object when auto-tuning is running will abort the procedure.