160
XtrapulsPac – User Guide
Chapter 3 - Reference
Sub Index
22
Description Configuration
2
Data Type
Integer16
Object Class
sq
Access rw
PDO Mapping
No
Default Value
0
For a homing sequence, this parameter defines the homing method.
Sub Index
23
Description Temporization
Data Type
Unsigned16
Object Class
sq
Access rw
PDO Mapping
No
Unit ms
Value Range
0…16000
Default Value
0
Sub Index
24
Description Running
Time
Data Type
Unsigned16
Object Class
sq
Access rw
PDO Mapping
No
Unit ms
Value Range
Default Value
0
For a speed sequence or a torque sequence, if the Running Time is 65535 (maximum of 16-bit), then the running
phase will be executed forever. An "End Condition" can be used to exit this sequence.
Sub Index
25
Description Analog
In
Data Type
Integer16
Object Class
sq
Access rw
PDO Mapping
No
Unit
16-bit scaled value
Value Range
Default Value
0
For a torque sequence, this parameter defines the torque value.
For a homing sequence, this parameter defines the home current limit value.
Sub Index
26
Description
Analog In 2 (reserved for futur use)
Data Type
Integer16
Object Class
sq
Access rw
PDO Mapping
No
Unit
16-bit scaled value
Value Range
Default Value
0