138
XtrapulsPac – User Guide
Chapter 3 - Reference
This parameter defines the torque slope when the target torque is changed.
Index 0x6087
Name Torque
Slope
Object Code
VAR
Data Type
Unsigned32
Object Class
pt
Access rw
PDO Mapping
No
Unit
per thousand of rated current per second
Value Range
-
Default Value
0x10000
"DC Voltage" gives the value of the DC voltage in the drive. This signal is filtered by a low-pass filter (0x3408-2)
Index 0x6079
Name DC
Voltage
Object Code
VAR
Data Type
Integer32
Object Class
all
Access ro
PDO Mapping
Yes
Unit mV
Value Range
-
Default Value
-
3.2.3.8 - Sequence Mode
The purpose of the sequencer mode is to allow basic moves.
A basic move is called "sequence" and a list of sequences can be pre-programmed and stored in the drive.
Each sequence is identified with a number (sequence number).
The maximum number of sequences for a given drive is shown in object 0x3612
The different sequence types are the following:
- Positioning
sequence
- Homing
sequence
- Speed
sequence
- Torque
sequence
- Gearing
sequence
NOTE: depending on model and/or firmware version, not all sequence types above are supported. The sequence
types supported are shown in object 0x360F
Various sequences can be sequentially linked together to build a complex move.
Sequence 0
Sequence 1
Sequence n-1
Sequence number
Position Setpoint
Sequencer
Logic Outputs
Start Condition
Start
End Condition
+
-
to position loop
Offset