66
XtrapulsPac – User Guide
Chapter 3 - Reference
46
Extension Error or Fieldbus watchdog
error
0x8181 Communication
47
Extension Error or Fieldbus hardware
error
0x50B2 Device
Hardware
48
Extension Error or Fieldbus hardware
error
0x50B3 Device
Hardware
49
Fieldbus SYNC cycle error
0x8780
Sync Controller
50
Fieldbus IP reference underflow/overflow
0x8782
Sync Controller
51
Fieldbus guarding error
0x8130
Life Guard Error or Heartbeat Error
52 reserved
0x1000
53
SD card error (not for standard
XtrapulsPac)
0x7600
Data Storage (external)
54
File Erase/Write Error
0x6320
Parameter Error
55
Watchdog error
0x5220
Control: Computing circuit
56
Safety channel 1 (STO) Error
0x9081
External Error
57
User Code Error
0x6282
User Software
58
CAN Extension Module communication
lost or not found
0x7580 Communication
59 reserved
0x1000
60
Stop Operation failed or speed/position
monitoring failed
0xFF10 Manufacturer
specific
61
Encoder: Commutation channel /
Incremental channel error
0x7305
Incremental sensor 1 fault
62
Encoder: Absolute channel error
0x7305
Incremental sensor 1 fault
63
User Program Error (not for standard
XtrapulsPac)
0x6280 User
Software
64
Procedure error (Auto-tuning, auto-
phasing...)
0xFFA2 Manufacturer
specific
3.2.1.2.2 - Warning
Warning:
Warning is displayed in object 0x3024,0 (32-bit).
Warning bit in status (bit 7) is also set.
Warning cannot be cleared by the user, it will automatically be cleared when the origin of the warning is
discarded.
Warning Code
Index 0x3024
Name Warning
Code
Object Code
VAR
Data Type
Unsigned32
Object Class
all
Access ro
PDO Mapping
Possible
Default Value
0