219
XtrapulsPac - User Guide
Chapter 3 – Reference
Analog Inputs Assignment
Index 0x3823
Name
Analog Inputs Assignment
Object Code
RECORD
Number of Elements
3
Value Description
Analog input can be assigned to a drive's variable:
variable = (analog_input - offset) x gain / 256
Sub Index
1
Description Target
Variable
Data Type
Unsigned32
Access rw
Save Yes
PDO Mapping
No
Default Value
0
This parameter allows connecting the analog input to a drive's variable.
The structure of the entries is the following:
MSB
LSB
Index (16-bit)
Sub-index (8-bit)
size (bits)
Sub Index
2
Description Offset
Data Type
integer16
Access rw
Save Yes
PDO Mapping
No
Default Value
0
Sub Index
3
Description Gain
Data Type
integer16
Access rw
Save Yes
PDO Mapping
No
Default Value
256
Index/sub
Analog Input
0x3829,3
Offset
0x3823,2
Gain/256
0x3823,3
Target object
0x3823,1
+
-
CANopen
I/O Module
Analog
Input
CAN bus