186
XtrapulsPac – User Guide
Chapter 3 - Reference
Bit Number Function
0..1 Exit
Mode:
0 slowdown
1 immediate
Exit Mode allows exiting immediately the gearbox sequence and link to another
sequence without stopping the motor.
2..3 Coupling
Mode:
0
with speed ramp (constant acceleration)
1
with constant distance (variable acceleration)
2
with speed ramp and position correction
4..5 Trigger
Mode:
0 immediate
1
on logic input rising edge
6..7 Start
Mode:
0
relative to initial position
1
absolute to master position (modulo)
8
Ratio set select
0
ratio set 1
1
ratio set 2
9
0
ratio set selection by bit 8.
1
allows ratio set selection by master-slave control (0x3940,0 bit 8)
10
Ratio modulation Enable
11 Reserved
12
Forward only: prevents from slave moves in negative direction.
If master goes in negative direction, an error will be notified in master-slave status
(0x3941,0)
13
Reverse direction: reverse slave direction.
14..15 Reserved
Sub Index
2
Description Gearbox
Ratio
Factor
Data Type
Unsigned16
Access rw
PDO Mapping
Possible
This parameter defines a ratio factor applied to the master-slave ratio,
Factor = Gearbox_Ratio_Factor / 32768
If Gearbox_Ratio_Factor = 0, no ratio Factor is applied.
In a gearing sequence, an equivalence factor is defined in sequence parameter with a different value for each
gearing sequence.