89
XtrapulsPac - User Guide
Chapter 3 – Reference
Sub Index
2
Description
Motor temperature warning threshold
Data Type
Unsigned32
Access rw
PDO Mapping
No
Unit
Ω
(ohm)
Default value
2400
This parameter defines the threshold of the equivalent resistor corresponding to the temperature at which a
warning will be notified.
Sub Index
3
Description
Motor temperature error threshold
Data Type
Unsigned32
Access rw
PDO Mapping
No
Unit
Ω
(ohm)
Default value
2400
This parameter defines the threshold of the equivalent resistor corresponding to the temperature at which an error
will be triggered.
Index 0x3323
Name
Motor temperature probe monitoring
Object Code
VAR
Data Type
Unsigned32
Object Class
all
Access ro
Unit
Ω
(ohm)
PDO Mapping
No
The returned value gives an image of the equivalent resistance (in
Ω
).
3.2.2.6 - IGBT temperature
IGBT module temperature value
Index 0x3328
Name
IGBT module temperature information
Object Code
VAR
Data Type
Integer 16
Object Class
all
Access ro
PDO Mapping
Yes
Unit °C
Remark
Only valid for the 400 V range