190
XtrapulsPac – User Guide
Chapter 3 - Reference
Digital Outputs
Index 0x60FE
Name Digital
Output
Object Code
ARRAY
Number of Elements
2
Value Description
Sub Index
1
Description Digital
Output
Data Type
Unsigned32
Access rw
PDO Mapping
Possible
Default Value
0
bit Function
0 Motor
Brake
1
2
3
14
15
16
OUT1
Physical Output 1
17
OUT2
Physical Output 2
18
OUT3
Physical Output 3
19
20
21
22
23
24
25
26
27
28
29
30
31
Sub Index
2
Description
Digital Output Bitmask
Data Type
Unsigned32
Access rw
PDO Mapping
No
Default Value
0
If the Digital Output Bitmask corresponding to "Motor Brake" (bit 0) is set, the sub 1 allows the manual control of
the motor brake. Otherwise, the motor brake is automatically controlled when the drive is enabled/disabled with a
delay.