113
XtrapulsPac - User Guide
Chapter 3 – Reference
Sub Index
2
Description
External Feedforward Speed
Data Type
Integer32
Access rw
PDO Mapping
Yes
Unit
Velocity unit: User inc / s
Default Value
0
Sub Index
3
Description
External Feedforward Acceleration
Data Type
Integer32
Access rw
PDO Mapping
Yes
Unit
Acceleration unit: User inc / s
2
Default Value
0
3.2.2.10 - Auto-tuning
Auto-tuning Parameters
Index 0x3425
Name
Auto-tuning parameters
Object Code
ARRAY
Number of Elements
4
Value Description
All these parameters must be set before starting the auto-tuning by 0x3426.
Sub Index
1
Description Auto-tuning
Bandwidth
Data Type
Unsigned16
Object Class
-
Access rw
PDO Mapping
No
Value Range
0..2
Default Value
This parameter defines the auto-tuning bandwidth:
Value Bandwidth
0 Low
Bandwidth
1 Medium
Bandwidth
2 High
Bandwidth
Sub Index
2
Description Filter
type
Data Type
Unsigned16
Object Class
-
Access rw
PDO Mapping
No
Value Range
0..2
Default Value