222
XtrapulsPac – User Guide
Chapter 3 - Reference
Sub Index
3
Description
I/O Module's RPDO numbers
Number of RPDO receiving digital/analog outputs from drive
Data Type
Unsigned16
Access rw
Save Yes
PDO Mapping
No
Default Value
0x0001
Bit Number Function
0..7
Module's RPDO for digital outputs
0 Not
used
1..4
RPDO1 to RPDO4
8..15
Module's RPDO analog output
0 Not
used
1..4
RPDO1 to RPDO4
Sub Index
4
Description
Module's TPDO numbers
Number of TPDO transmitting digital/analog inputs to drive
Data Type
Unsigned16
Access rw
Save Yes
PDO Mapping
No
Default Value
0x0001
Bit Number Function
0..7 Module's
TPDO
for digital inputs
0 Not
used
1..4
RPDO1 to RPDO4
8..15
Module's TPDO for analog input
0 Not
used
1..4
RPDO1 to RPDO4
CANopen IO module control parameters
Index 0x3828
Name
CANopen I/O control parameters
Object Code
RECORD
Number of Elements
4
Value Description
Sub Index
1
Description Node
ID
Data Type
Unsigned16
Access rw
Save yes
PDO Mapping
No
Value 0
Not
used
1..127 module node id
Sub Index
2
Description Control
Data Type
Unsigned16
Access rw
Save yes
PDO Mapping
No
This parameter defines the I/O module management.