178
XtrapulsPac – User Guide
Chapter 3 - Reference
The structure of the entries is the following:
MSB
LSB
Index (16-bit)
Sub-index (8-bit)
0
Example:
0x3944,0 = 0x30F20200
connects the Analog input 2 to the slave offset signal.
If this object is cleared, then the slave offset value is given from object 0x3943,0.
3.2.4.2 - Virtual Master
Virtual Master
Virtual master allows generating a position signal with a profile as shown below:
The profile starts as soon as the Virtual Master Speed is set with the defined acceleration, and the master signal
slows down and stops when Virtual Master Speed is reset at 0. The virtual master output object can be used as
master-slave input signal or distributed over CAN bus via PDO.
Virtual Master Objects Definition
Index Object
Name
Type
Attr.
0x3901
VAR
Virtual Master Speed Source
Unsigned32
rw
0x3902 VAR
Virtual
Master
Speed
Integer32
rw
0x3903 VAR
Virtual
Master
Acceleration
Integer32
rw
0x3906 VAR
Virtual
Master
Output
Integer32
rw
Virtual Master Speed Source
Index 0x3901
Name
Virtual Master Speed Source
Description Index/sub-index of input data
Data Type
Unsigned32
Class
sq, gb, cm
Access rw
PDO Mapping
No
Value See
below
Default Value
0
This object allows connecting any 32-bit dataflow as virtual master speed signal. The content of the virtual master
speed (0x3902,1) will be replaced by the content of the source.
speed
time