v
Frame control panel
v
SPCN frame-to-frame cable
This ends the procedure.
23.
Do SPCN optical cables
A
connect the failing frame
B
to the preceding frame
in the string?
┌─────────┐
(A) SPCN
│ System │ Optical Cables ─┐
┌───── SPCN
│ Unit
│
│
:
Optical
│
J15
│
┌─┐
:
┌─┐
Adapter
└────┬────┘
│ ├────────────┤ │
│
│ ├────────────┤ │
┌────┴────┐ ┌───────┴─┤
┌───────┴─┤ ┌─────────┐
│
J15
│ │
J16│
│
J15│ │
│
│Frame J16├─┤J15 Frame│
│Frame J16├─┤J15 Frame│
│ 1
│ │
2 │
│ 3
│ │
4 │
└─────────┘ └─────────┘
└─────────┘ └─────────┘
G
└──── (B) Failing Frame
Yes
No
↓
Go to step 27 on page 47 of this procedure.
24.
Remove the SPCN optical adapter
A
from the preceding frame in the string
that cannot become powered on. See the removal and installation procedures
in this book or in the
Migrated Expansion Tower Problem Analysis, Repair and
Parts
, depending on the secondary frame you are working on.
┌─────────┐
┌─── (A) SPCN Optical Adapter
│ System │
│
│ Unit
│
:
│
J15
│
┌─┐
┌─┐
└────┬────┘
│ ├────────────┤ │
│
│ ├────────────┤ │
┌────┴────┐ ┌───────┴─┤
┌───────┴─┤ ┌─────────┐
│
J15
│ │
J16│
│
J15│ │
│
│Frame J16├─┤J15 Frame│
│Frame J16├─┤J15 Frame│
│ 1
│ │
2 │
│ 3
│ │
4 │
└─────────┘ └─────────┘
└─────────┘ └─────────┘
G
│
└─── Failing Frame
25.
Perform the following:
a.
Connect the negative lead of a multimeter to the system frame ground.
b.
Connect the positive lead of a multimeter to pin 2 of J16 on the PCC, AC
module, or SPCN card in the frame from which you removed the SPCN
optical adapter in step 24 of this procedure.
Note:
If you are working on a system unit, the cable may be connected to
either J15 or J16. Use an insulated probe or jumper when
performing the voltage readings.
c.
Note the voltage reading on pin 2.
d.
Move the positive lead of the multimeter to pin 3 of J16 on the PCC.
e.
Note the voltage reading on pin 3.
1
2
3
4
5
6
7
8
9
RV2A179-1
Is the voltage on both pin 2 and pin 3 from 1.5 V DC to 5.5 V DC?
Power Problems
46
iSeries Model 830, 840, SB2, and SB3 Problem Analysis, Repair and Parts V5R1
Summary of Contents for i 830
Page 2: ......
Page 14: ...xii iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 15: ...Part 1 Problem Analysis Copyright IBM Corp 2000 2001 1...
Page 16: ...2 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 628: ...Symbolic FRUs 614 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 629: ...Part 2 FRU Replacement Copyright IBM Corp 2000 2001 615...
Page 630: ...616 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 817: ...Part Assemblies Chapter 5 Locations Addresses and Part Listings 803...
Page 897: ...Miscellaneous Chapter 5 Locations Addresses and Part Listings 883...
Page 906: ...892 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 962: ...948 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 963: ...Part 3 Appendixes Copyright IBM Corp 2000 2001 949...
Page 964: ...950 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 968: ...954 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 970: ...956 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 974: ...960 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 980: ...966 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 982: ...968 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 984: ...970 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 986: ...972 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 990: ...976 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 999: ......