Reference
Code
Description/Action Perform all actions before exchanging
Failing Items
Failing Item
Location
5083
IPL service function ended abnormally
A service program lost contact with the system console.
Perform “TWSC-PIP1” on page 465.
AJDG301
UG3USR1
5090
System startup failed in unattended IPL mode
Perform the following:
v
If reference code A6005090 is displayed on the control panel
for more than 10 minutes, perform “LIC-PIP 11” on page 350.
v
For reference code B6005090, perform “LIC-PIP 11” on
page 350.
FI00580
FI00500
FI00301
FI00021
FI00065
AJDG301
5092
System is in DASD migration mode
“Install Licensed Internal Code” and “Upgrade Load Source”
was specified but the key is not in the manual position. Change
the key position to manual and perform a system IPL.
5094
IASP detected a failure during the vary on operation
Perform “LIC-PIP 12” on page 363.
SVCDOCS
50FF
DST unrecoverable program error
Perform “LIC-PIP3” on page 344.
AJDG301
FI00380
5120
System LIC detected a program exception
System LIC detected a programming problem. If performance
or other system degradation is occurring, the system may be
operating with reduced resources.
Check the Product activity log for related entries. If this
reference code is logged with a
Class
of Informational, then no
action is required.
Otherwise, perform “LIC-PIP1” on page 342 in “Licensed
Internal Code (LIC) Problem Isolation Procedures” on page 341.
AJDG301
FI00130
5121
System LIC program exception occurred
System LIC detected a programming problem for which a main
storage dump may have been initiated.
A problem log entry may be generated for this ref code.
Perform “LIC-PIP1” on page 342.
AJDG301
5122
System LIC program exception occurred
System LIC detected an IOP programming problem for which
an IOP dump may have been initiated.
Perform “LIC-PIP1” on page 342.
FI00130
AJDG301
FI00131
5123
System LIC program exception occurred
System LIC detected an interface problem with the IOP or an
IOP programming problem for which an IOP and main storage
dump may have been initiated.
Perform “LIC-PIP1” on page 342.
FI00130
AJDG301
FI00131
B6xx (including A6xx)
Chapter 2. Unit Reference Codes
249
Summary of Contents for i 830
Page 2: ......
Page 14: ...xii iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 15: ...Part 1 Problem Analysis Copyright IBM Corp 2000 2001 1...
Page 16: ...2 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 628: ...Symbolic FRUs 614 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 629: ...Part 2 FRU Replacement Copyright IBM Corp 2000 2001 615...
Page 630: ...616 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 817: ...Part Assemblies Chapter 5 Locations Addresses and Part Listings 803...
Page 897: ...Miscellaneous Chapter 5 Locations Addresses and Part Listings 883...
Page 906: ...892 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 962: ...948 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 963: ...Part 3 Appendixes Copyright IBM Corp 2000 2001 949...
Page 964: ...950 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 968: ...954 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 970: ...956 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 974: ...960 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 980: ...966 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 982: ...968 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 984: ...970 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 986: ...972 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 990: ...976 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 999: ......