Failing Item Code
Description/Action
If only a type number is listed, go to the “Type, Model, and Part
Number list” on page 885 to determine the part number.
FI01105
FI01105 indicates that the addressed storage device is the failing item.
Perform the following:
1.
Is the device location information available in the Service Action Log?
No
Yes
↓
Exchange the failing item. See “Recovery Procedures” on page 893.
Note:
If the failing item is in a migration tower, go to recovery procedures in
the
Migrated Expansion Tower Problem Analysis, Repair and Parts
.
This ends the procedure.
2.
Find the IOP address and the device address (see “SRC Address Formats” on page 936).
3.
To determine the location of the I/O processor card, see “Locations and Addresses” on
page 705 and find the diagram of the system unit or the expansion unit. Then, find:
v
The IOP card location identified by the direct select address.
v
The addressed storage device location identified by the device address.
4.
Exchange the failing device. Use the device type to determine the part.
FI01106
FI01106 indicates that a storage device other than the addressed storage device is the failing
item.
See FI01105 to find the addressed device. The failing item could be any device with the
same IOP address and I/O (SCSI) bus number but with a different device unit number.
If the reference code that called out this FI does not have a problem analysis procedure,
perform “SDIOP-PIP16” on page 407 to isolate the possible failing device.
FI01107
FI01107 indicates that any storage device attached to the I/O (SCSI) bus of this IOP may be
the failing item.
Perform the following:
1.
Find the IOP address (see “SRC Address Formats” on page 936).
2.
To determine the location of the I/O processor card, see “Locations and Addresses” on
page 705.
The unit reference code indicates the I/O (SCSI) bus that has the problem:
v
URC 3020, 3100 —I/O Bus 0
v
URC 3021, 3101 —I/O Bus 1
v
URC 3022, 3102 —I/O Bus 2
v
Any Other URC—Any I/O bus on the I/O card
3.
See “Locations and Addresses” on page 705 and find the diagram of the system unit or
the expansion unit and find:
v
The IOP card location identified by the direct select address.
v
All the storage devices on the same I/O (SCSI) bus.
Note:
The I/O (SCSI) bus number is the first character of the device unit address.
4.
Exchange the failing device. Use the device type to determine the part:
If the reference code that called out this FI does not have a problem analysis procedure,
perform “SDIOP-PIP16” on page 407 to isolate the possible failing device.
FI01108
FI01108 indicates that the I/O (SCSI) bus or power cable is the failing item.
See FI01140 and FI01141.
FI01109
A backplane or a connection to the backplane may be failing.
See the symbolic FRU “BACKPLN” on page 504.
Failing Items
Chapter 3. Problem Isolation Procedures (PIPs), Failing Items, and Symbolic FRU Isolation
493
Summary of Contents for i 830
Page 2: ......
Page 14: ...xii iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 15: ...Part 1 Problem Analysis Copyright IBM Corp 2000 2001 1...
Page 16: ...2 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 628: ...Symbolic FRUs 614 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 629: ...Part 2 FRU Replacement Copyright IBM Corp 2000 2001 615...
Page 630: ...616 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 817: ...Part Assemblies Chapter 5 Locations Addresses and Part Listings 803...
Page 897: ...Miscellaneous Chapter 5 Locations Addresses and Part Listings 883...
Page 906: ...892 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 962: ...948 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 963: ...Part 3 Appendixes Copyright IBM Corp 2000 2001 949...
Page 964: ...950 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 968: ...954 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 970: ...956 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 974: ...960 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 980: ...966 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 982: ...968 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 984: ...970 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 986: ...972 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 990: ...976 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 999: ......