Reference
Code
Description/Action Perform all actions before exchanging
Failing Items
Failing Item
Location
5312
System LIC program exception occurred
LPAR configuration data informational error.
The LPAR configuration data was found to be or inconsistent
on a secondary partition’s load source. The data was
automatically updated to the current system level.
5313
System LIC program exception occurred
LPAR configuration data informational error.
The LPAR configuration data was found to be inconsistent on a
primary partition and could only be corrected with an older
copy of the data.
LPARCFG
5340
Secondary partition not running at optimum.
Check the Primary partition’s Product Activity Log for system
processor entries from approximately the same time. Perform
the actions indicated for those entries. For more information on
Logical Partitioning, see the Logical Partitioning Information in
the
iSeries Service Functions
.
5341
Secondary partition not running at optimum.
Check the primary partition Product Activity Log for system
memory entries from approximately the same time. Perform the
actions indicated for those entries. For more information on
Logical Partitioning, see the Logical Partitioning Information in
the
iSeries Service Functions
.
5342
Secondary partition not running at optimum.
Check the Primary partition’s Product Activity Log for system
processor entries from approximately the same time. Perform
the actions indicated for those entries. For more information on
Logical Partitioning, see the Logical Partitioning Information in
the
iSeries Service Functions
.
5343
Secondary partition not running at optimum.
Check the Primary partition’s Product Activity Log for system
memory errors from approximately the same time. Perform the
actions indicated for those entries.
For more information on Logical Partitioning see the Logical
Partitioning Information in the
iSeries Service Functions
.
5344
Secondary partition not running at optimum.
The interactive performance specified in the configuration data
for this partition could not be met.
Contact your next level of support.
LPARSUP
B6xx (including A6xx)
252
iSeries Model 830, 840, SB2, and SB3 Problem Analysis, Repair and Parts V5R1
Summary of Contents for i 830
Page 2: ......
Page 14: ...xii iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 15: ...Part 1 Problem Analysis Copyright IBM Corp 2000 2001 1...
Page 16: ...2 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 628: ...Symbolic FRUs 614 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 629: ...Part 2 FRU Replacement Copyright IBM Corp 2000 2001 615...
Page 630: ...616 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 817: ...Part Assemblies Chapter 5 Locations Addresses and Part Listings 803...
Page 897: ...Miscellaneous Chapter 5 Locations Addresses and Part Listings 883...
Page 906: ...892 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 962: ...948 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 963: ...Part 3 Appendixes Copyright IBM Corp 2000 2001 949...
Page 964: ...950 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 968: ...954 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 970: ...956 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 974: ...960 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 980: ...966 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 982: ...968 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 984: ...970 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 986: ...972 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 990: ...976 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 999: ......