Table 33. (continued)
System Model,
Tower,
Expansion
Unit, or
Machine Type
Name of FRU
to Exchange
FRU Position
Link to
Location
Diagram
Link to Failing
Component Service
Information. (CCIN,
PN, Removal and
Installation Procedure)
FC 5033, FC
5034, or FC
5035 SPD
Migrated
Tower
Go to symbolic FRU CVTCARD in the
Migrated Expansion Tower Problem
Analysis, Repair and Parts
.
This ends the procedure.
SI_PHB
SI_PHB: high-speed link PCI host bridge.
The HSL I/O bridge hardware in a base I/O tower or I/O expansion tower is
failing. Follow the procedure to identify the failing component to exchange.
1.
If you are working from the Service Action Log and a card position is listed
with this FRU, then that is where the error is located, continue with the next
step in this procedure. Otherwise, record the bus number value, BBBB, in word
7 of the SRC, see “Breaking Down The SRC” on page 280 for help in
determining the bus number. Search for the bus number in HSM or the System
Configuration Listing to determine which frame or I/O tower contains the
failing item. Record the frame or tower type.
2.
Use the system model, tower, expansion unit or machine type and the table
below to determine the service information for the failing component.
Table 34.
System Model,
Tower,
Expansion
Unit, or
Machine Type
Name of FRU
to Exchange
FRU Position
Link to
Location
Diagram
Link to Failing
Component Service
Information. (CCIN,
PN, Removal and
Installation Procedure)
FC 5074
HSL I/O
Bridge Card
C08
“Locations —
FC 5074 I/O
Tower” on
page 736.
Table 44 on page 737.
FC 5075
Tower Card
CB1
“Locations —
FC 5075 I/O
Tower” on
page 740.
Table 45 on page 741.
FC 5078/0578
HSL I/O
Bridge Card
C08
“Locations —
FC 5078, 0578
PCI Expansion
Unit” on
page 743.
Table 46 on page 744.
FC 5079 (1.8m
expansion
tower)
HSL I/O
Bridge Card
C08
“Locations —
FC 5079 I/O
Tower” on
page 747.
Table 44 on page 737.
Symbolic FRUs
Chapter 3. Problem Isolation Procedures (PIPs), Failing Items, and Symbolic FRU Isolation
587
Summary of Contents for i 830
Page 2: ......
Page 14: ...xii iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 15: ...Part 1 Problem Analysis Copyright IBM Corp 2000 2001 1...
Page 16: ...2 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 628: ...Symbolic FRUs 614 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 629: ...Part 2 FRU Replacement Copyright IBM Corp 2000 2001 615...
Page 630: ...616 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 817: ...Part Assemblies Chapter 5 Locations Addresses and Part Listings 803...
Page 897: ...Miscellaneous Chapter 5 Locations Addresses and Part Listings 883...
Page 906: ...892 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 962: ...948 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 963: ...Part 3 Appendixes Copyright IBM Corp 2000 2001 949...
Page 964: ...950 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 968: ...954 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 970: ...956 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 974: ...960 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 980: ...966 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 982: ...968 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 984: ...970 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 986: ...972 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 990: ...976 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 999: ......