Notes:
1.
If the failing item is a failing item (FI) code, go to “Failing Items” on page 479
to determine which part number associated with the FI code is failing.
2.
If the failing item is a type number, go to “Type, Model, and Part Number list”
on page 885 to determine the part number.
3.
If the failing item is a symbolic FRU, go to “Symbolic FRUs” on page 495 to
determine the part number.
Reference Code
Description/Action Perform all actions before exchanging Failing Items
Failing Item
00A0
SPCN BATs in process
No action required. This reference code is logged for information only. If
this reference code is present for more than 1 minute, exchange the failing
items.
TWRCARD
00A1
Regulator 1 has been turned off by system
No action required. This reference code is logged for information only.
00A2
Regulator 2 has been turned off by system
No action required. This reference code is logged for information only.
00A3
Regulator 3 has been turned off by system
No action required. This reference code is logged for information only.
00A4
Regulator 4 has been turned off by system
No action required. This reference code is logged for information only.
00A5
Regulator 5 has been turned off by system
No action required. This reference code is logged for information only.
00A6
Regulator 6 has been turned off by system
No action required. This reference code is logged for information only.
00A7
The system is running on the Battery Power Unit.
No action required. This reference code is logged for information only.
00A8
The Battery Power Unit is not fully charged.
No action required. This reference code is logged for information only.
00A9
Battery Power Unit test is in process.
No action required. This reference code is logged for information only.
00AA
Download in process
No action required. This reference code is logged for information only.
00AB
Rack UEPO switch is OFF.
Informational reference code.
The UEPO switch must be returned to the On position to power on the
rack.
TWRCARD
CTLPNL
6462417
00AC
Detected AC loss
If system powers on normally or stays powered on after AC power failure,
no replacement of parts may be needed.
ACMODUL
1xxx
Chapter 2. Unit Reference Codes
65
Summary of Contents for i 830
Page 2: ......
Page 14: ...xii iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 15: ...Part 1 Problem Analysis Copyright IBM Corp 2000 2001 1...
Page 16: ...2 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 628: ...Symbolic FRUs 614 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 629: ...Part 2 FRU Replacement Copyright IBM Corp 2000 2001 615...
Page 630: ...616 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 817: ...Part Assemblies Chapter 5 Locations Addresses and Part Listings 803...
Page 897: ...Miscellaneous Chapter 5 Locations Addresses and Part Listings 883...
Page 906: ...892 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 962: ...948 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 963: ...Part 3 Appendixes Copyright IBM Corp 2000 2001 949...
Page 964: ...950 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 968: ...954 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 970: ...956 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 974: ...960 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 980: ...966 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 982: ...968 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 984: ...970 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 986: ...972 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 990: ...976 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 999: ......