How to Analyze the Intermittent Problem
1.
Is a reference code associated with the intermittent problem?
No
Yes
↓
Go to “Chapter 2. Unit Reference Codes” on page 59 and find the
reference code. If the actions in the unit reference code tables do not
correct the intermittent problem, return here and continue with the next
step of this procedure.
2.
Is a symptom associated with the intermittent problem?
No
Yes
↓
Go to “Intermittent Symptom Table”. If the Intermittent Symptom Table
does not correct the intermittent problem, return here and continue
with the next step of this procedure.
3.
Go to “Failing Area INT-PIP Table” on page 21. If the Failing Area INT-PIP
Table does not correct the intermittent problem, return here and continue with
the next step of this procedure.
4.
Send the data you have collected to your next level of support so that an
Authorized Program Analysis Report (APAR) or a Licensed Internal Code
Trouble Report (LICTR) can be written.
This ends the procedure.
Intermittent Symptom Table
1.
In the
Symptom
column, find the failure symptom.
2.
In the
Description
column, read the description of the failure.
3.
In the
INT-PIPs
column, perform the INT-PIPs shown for that symptom
beginning at “Intermittent Problem Isolation Procedures” on page 332.
Although an INT-PIP may correct the intermittent problem, use your best
judgment to determine if you should perform the remainder of the INT-PIPs
shown for the symptom.
If the symptom for the intermittent problem you have is not listed, go to “Failing
Area INT-PIP Table” on page 21.
Symptom
Description
INT-PIPs
System becomes
powered off.
The system was operating correctly, then the system became
powered off. SRC 0000 111x may occur when this happens,
but the SRC information is lost if the customer performs an
IPL after the failure and does not record the SRC.
Notes:
1.
If the system has no workstation I/O processor cards,
omit INT-PIP5.
2.
If the system has an uninterruptable power supply
(UPS), perform “INT-PIP9 Utility Power and Battery
Power Units” on page 336.
“INT-PIP5 External Noise on
Twinaxial Cables” on page 333,
“INT-PIP9 Utility Power and
Battery Power Units” on page 336
System stops.
The system is powered on but is not operating correctly. No
SRC or error code is displayed. The System Attention light
is off. The Processor Activity lights may be on or off. Noise
on the power-on reset line can cause the processor to stop.
Note:
Ensure that the latest service processor PTF for your
release is installed.
“INT-PIP18 PTFs Not Installed”
on page 339
Intermittent Problems
20
iSeries Model 830, 840, SB2, and SB3 Problem Analysis, Repair and Parts V5R1
Summary of Contents for i 830
Page 2: ......
Page 14: ...xii iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 15: ...Part 1 Problem Analysis Copyright IBM Corp 2000 2001 1...
Page 16: ...2 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 628: ...Symbolic FRUs 614 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 629: ...Part 2 FRU Replacement Copyright IBM Corp 2000 2001 615...
Page 630: ...616 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 817: ...Part Assemblies Chapter 5 Locations Addresses and Part Listings 803...
Page 897: ...Miscellaneous Chapter 5 Locations Addresses and Part Listings 883...
Page 906: ...892 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 962: ...948 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 963: ...Part 3 Appendixes Copyright IBM Corp 2000 2001 949...
Page 964: ...950 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 968: ...954 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 970: ...956 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 974: ...960 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 980: ...966 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 982: ...968 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 984: ...970 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 986: ...972 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 990: ...976 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 999: ......