5.
Use the “Licensed Internal Code log” service function under DST/SST to copy
the LIC log entries to removable media for the day that the problem occurred.
6.
Copy the system configuration list (see “Hardware Service Manager, Printing
the System Configuration List” in the
iSeries Service Functions
information).
7.
Provide the dumps to IBM Service Support.
8.
Check the Logical Hardware Resource STATUS field using Hardware Service
Manager. If the status is not
Operational
then IPL the IOP using the I/O Debug
option (Ignore resources with a status of
not connected)
.
To IPL a failed IOP, the following command can be used:
VRYCFG CFGOBJ(XXXX)
CFGTYPE(*CTL) STATUS(*RESET)
or use DST/SST Hardware Service Manager.
If the IPL does not work:
v
Check the Service Action Log for new SRC entries (see “Using the Service
Action Log” on page 9). Use the new SRC and go to “Chapter 2. Unit
Reference Codes” on page 59.
v
If there are no new SRCs in the Service Action Log, go to “BUS-PIP1” on
page 285.
This ends the procedure.
9.
Has the system stopped but the DST console is still active (Did the SRC come
from the Main Storage Dump manager screen on the DST console)?
Yes
No
↓
Go to step 15 of this procedure.
10.
Complete a Problem Summary Form using the information in words 1–9 from
the control panel, or from the DST Main Storage Dump screen (see “Error
Recovery for Dumps, Reporting the Error” in the
iSeries Service Functions
information).
11.
The system has already taken a partial main storage dump for this SRC and
automatically re-IPLed to DST (see “Automatic Main Storage Dump” in the
iSeries Service Functions
information).
12.
Copy the main storage dump to tape (see “Copying a Main Storage Dump” in
the
iSeries Service Functions
information).
13.
When the dump is completed, the system will re-IPL automatically. Sign on to
DST or SST. Obtain the data in steps 3, 4, 5, and 6 of this procedure.
14.
Provide the dumps to IBM Service Support.
This ends the procedure.
15.
Has the system stopped with an SRC at the control panel?
Yes
No
↓
Go to step 1 of this procedure.
16.
Complete a Problem Summary Form using the information in words 1–9 from
the control panel, or from the DST Main storage dump screen (see “Error
Recovery for Dumps, Reporting the Error” in the
iSeries Service Functions
information).
17.
IPL to DST and start the Main storage dump manager service function.
18.
Copy the main storage dump to tape (see “Copying a Main Storage Dump” in
the
iSeries Service Functions
information).
19.
Obtain the data in steps 3, 4, 5, and 6 of this procedure.
20.
Re-IPL the system.
21.
Has the system stopped with an SRC at the control panel?
LIC PIPs
Chapter 3. Problem Isolation Procedures (PIPs), Failing Items, and Symbolic FRU Isolation
343
Summary of Contents for i 830
Page 2: ......
Page 14: ...xii iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 15: ...Part 1 Problem Analysis Copyright IBM Corp 2000 2001 1...
Page 16: ...2 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 628: ...Symbolic FRUs 614 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 629: ...Part 2 FRU Replacement Copyright IBM Corp 2000 2001 615...
Page 630: ...616 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 817: ...Part Assemblies Chapter 5 Locations Addresses and Part Listings 803...
Page 897: ...Miscellaneous Chapter 5 Locations Addresses and Part Listings 883...
Page 906: ...892 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 962: ...948 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 963: ...Part 3 Appendixes Copyright IBM Corp 2000 2001 949...
Page 964: ...950 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 968: ...954 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 970: ...956 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 974: ...960 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 980: ...966 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 982: ...968 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 984: ...970 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 986: ...972 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 990: ...976 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 999: ......