b.
Try the new power supply in each of the other positions listed in the table.
c.
If the problem still is
not
fixed, reinstall the original power supply and go
to the next FRU in the list.
2.
Is the SRC 1xxx-13xx?
No
Yes
↓
For 1xxx-13xx SRCs use this table:
Unit Reference Code
Power Supply
Part Number
1300
P01
21H7719
1301
P02
21H7719
1302
P03
21H7719
1303
P04
21H7719
1304
P05
21H7719
1305
P06
21H7719
Notes:
a.
If the new power supply doesn’t fix the problem, reinstall the original
power supply.
b.
Try the new power supply in each of the other positions listed in the table.
c.
If the problem still is
not
fixed, reinstall the original power supply and go
to the next FRU in the list.
3.
Is the SRC 1xxx-15xx or 19xx?
No
Yes
↓
For 1xxx-15xx or 19xx SRCs in a system unit or secondary I/O frame
with single AC line cord, except FC 5078/0578, use this table:
Unit Reference Code
Power Supply
Part Number
1510, 1511, 1512, 1513,
1514, 1516
P01
90H6629
1520, 1521, 1522, 1523,
1524, 1526
P02
90H6629
1530, 1531, 1532, 1533,
1534, 1536
P03
90H6629
1910, 1911, 1912, 1913
PP1
24L0728
1920, 1921, 1922, 1923
PP2
24L0728
Notes:
a.
If the new power supply doesn’t fix the problem, reinstall the
original power supply.
b.
Try the new power supply in each of the other positions listed in
the table.
c.
If the problem still is
not
fixed, reinstall the original power supply
and go to the next FRU in the list.
For 1xxx-15xx and 19 xx SRCs in a system unit or secondary I/O
frame with dual AC line cord, except FC 5078/0578, use this table:
Also perform “Power PIP11” on page 396.
Symbolic FRUs
Chapter 3. Problem Isolation Procedures (PIPs), Failing Items, and Symbolic FRU Isolation
577
Summary of Contents for i 830
Page 2: ......
Page 14: ...xii iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 15: ...Part 1 Problem Analysis Copyright IBM Corp 2000 2001 1...
Page 16: ...2 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 628: ...Symbolic FRUs 614 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 629: ...Part 2 FRU Replacement Copyright IBM Corp 2000 2001 615...
Page 630: ...616 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 817: ...Part Assemblies Chapter 5 Locations Addresses and Part Listings 803...
Page 897: ...Miscellaneous Chapter 5 Locations Addresses and Part Listings 883...
Page 906: ...892 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 962: ...948 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 963: ...Part 3 Appendixes Copyright IBM Corp 2000 2001 949...
Page 964: ...950 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 968: ...954 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 970: ...956 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 974: ...960 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 980: ...966 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 982: ...968 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 984: ...970 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 986: ...972 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 990: ...976 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 999: ......