Table 1. Start Table (continued)
Symptom
What You Should Do
There is an IPL problem (the system
attention light is off and no SRC in function
5).
Go to “Analyzing IPL Problems” on page 22.
There is a
″
Device Not Found
″
message
during an install from an alternate
installation device.
Go to “TU-PIP6” on page 459.
System operations have stopped or the
system is in a loop (the system attention
light is off).
Go to “System Hangs or Loops (No SRC)”
on page 31.
On a system that has multiple logical partitions, there is a problem with a secondary
partition and the symptom is:
There is a B2xx xxxx SRC on the
Work with
Partition Status
screen of the Primary
console.
Go to “Chapter 2. Unit Reference Codes” on
page 59.
One or more of the following was reported:
v
The console of a secondary partition was
lost or is
not
functioning.
v
There is an SRC on the panel of an I/O
expansion tower owned by a secondary
partition.
v
You suspect a power problem with
resources owned by a secondary partition.
v
There is an IPL problem with a
secondary
partition
and there is an SRC on the
Work
with Partition Status
screen of the Primary
or secondary partition.
v
The
secondary partition’s
operations have
stopped or the partition is in a loop and
there is an SRC on the
Work with Partition
Status
screen of the Primary or secondary
console.
v
Search the Primary partition’s Service
Action Log. Go to “Using the Service
Action Log” on page 9.
v
If you don’t find an entry in the Service
Action Log of the Primary partition then
record the partition’s SRC from the
Work
with Partition Status
screen of the Primary
partition’s console. See
iSeries Service
Functions
. Use that SRC and go to
“Chapter 2. Unit Reference Codes” on
page 59.
Perform service from the secondary
partition unless instructed to move to
another partition.
The partition’s console is functioning
and
in
the
Work with partition status
screen in the
Primary partition or secondary partition, the
state of the partition is
″
Failed
″
or
″
Unit
Attn.
″
and there is a system reference code.
See
iSeries Service Functions
.
Use the partition’s SRC. From the partition’s
console search for that SRC in the partition’s
Service Action Log. Go to “Using the Service
Action Log” on page 9.
One or more of the following was reported:
v
There is an IPL problem with the
secondary partition and there is
no
SRC
displayed in the
Work with Partition Status
screen.
v
The partition’s operations have stopped or
the partition is in a loop and there is
no
SRC displayed in the
Work with Partition
Status
screen.
v
Go to “Logical Partition Hangs or Loops
(No SRC)” on page 34.
Starting Point
Chapter 1. Starting Problem Analysis
7
Summary of Contents for i 830
Page 2: ......
Page 14: ...xii iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 15: ...Part 1 Problem Analysis Copyright IBM Corp 2000 2001 1...
Page 16: ...2 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 628: ...Symbolic FRUs 614 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 629: ...Part 2 FRU Replacement Copyright IBM Corp 2000 2001 615...
Page 630: ...616 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 817: ...Part Assemblies Chapter 5 Locations Addresses and Part Listings 803...
Page 897: ...Miscellaneous Chapter 5 Locations Addresses and Part Listings 883...
Page 906: ...892 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 962: ...948 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 963: ...Part 3 Appendixes Copyright IBM Corp 2000 2001 949...
Page 964: ...950 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 968: ...954 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 970: ...956 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 974: ...960 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 980: ...966 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 982: ...968 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 984: ...970 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 986: ...972 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 990: ...976 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 999: ......