Go to step 71 of this procedure.
69.
Exchange the HSL Cable (see “SIRGCBL” on page 588).
70.
Is the leading port status of the HSL link from the
first
failing resource
″
failed
″
?
Yes
No
↓
The link is now functioning. Go to step 79 on page 298 of this
procedure.
71.
Exchange the Network interface controller (NIC) on the system unit (see
“SICNTRL” on page 584). Then go to step 79 on page 298 of this procedure.
72.
Is the HSL cable an optical HSL cable?
Yes
No
↓
Go to step 74 of this procedure.
73.
Examine the state of the LEDs associated with the optical ports where the
HSL cable connections are by performing the following: Determine which
LEDs to examine using the 13 table.
Examine both LEDs at the ports for each end of the optical cable. Are all four
(4) LEDs lighted?
No
Yes
↓
Go to step 76 of this procedure.
74.
Exchange the HSL cable between the
first
failing resource and the
second
failing resource using symbolic FRU “SIRGCBL” on page 588. Exchange only
the frame to frame cable. Do not exchange any internal HSL cables at this
time.
75.
Is the leading port status of the HSL link from the
first
failing resource
″
failed
″
?
Yes
No
↓
The link is now functioning. Go to step 79 on page 298 of this
procedure.
76.
Determine which FRU on the
second
failing resource to exchange using the
following table.
If the HSL trailing port on the second
failing resource is:
Exchange this FRU on the frame with the
second failing resource:
Port A0
HSL I/O Bridge using symbolic FRU
″
SIIOADP
″
in the Problem Analysis, Parts
and Repair document that supports that
system unit and model. In this document see
“SIIOADP” on page 585.
Ports B0, C0, D0, E0, F0, G0, H0
Network Interface Controller (NIC) using
symbolic FRU
″
SICNTRL
″
in the Problem
Analysis, Parts and Repair document that
supports that system unit and model. In this
document see “SICNTRL” on page 584.
Ports A1, B1, C1, D1, E1, F1, G1, H1
Network Interface Controller (NIC) using
symbolic FRU
″
SICNTRL
″
in the Problem
Analysis, Parts and Repair document that
supports that system unit and model. In this
document see “SICNTRL” on page 584.
Bus, High-Speed Link (HSL) PIPs
Chapter 3. Problem Isolation Procedures (PIPs), Failing Items, and Symbolic FRU Isolation
297
Summary of Contents for i 830
Page 2: ......
Page 14: ...xii iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 15: ...Part 1 Problem Analysis Copyright IBM Corp 2000 2001 1...
Page 16: ...2 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 628: ...Symbolic FRUs 614 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 629: ...Part 2 FRU Replacement Copyright IBM Corp 2000 2001 615...
Page 630: ...616 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 817: ...Part Assemblies Chapter 5 Locations Addresses and Part Listings 803...
Page 897: ...Miscellaneous Chapter 5 Locations Addresses and Part Listings 883...
Page 906: ...892 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 962: ...948 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 963: ...Part 3 Appendixes Copyright IBM Corp 2000 2001 949...
Page 964: ...950 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 968: ...954 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 970: ...956 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 974: ...960 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 980: ...966 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 982: ...968 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 984: ...970 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 986: ...972 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 990: ...976 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 999: ......