13.
Have you installed all of the power supplies that were removed in step 7 on
page 509 of this procedure?
Yes
No
↓
Repeat step 12 on page 510 of this procedure.
14.
Install all units removed in this procedure.
This ends the procedure.
15.
Perform the following:
a.
Power off the system.
b.
Install one of the regulators that was removed in step 2 on page 509 of this
procedure.
c.
Remove all bus load (processor, memory, and IOP except Clock card).
d.
Power on the system.
Is the SRC 1xxx 1200 displayed?
No
Yes
↓
The regulator installed in this step is the failing item.
This ends the procedure.
16.
Have you installed all of the regulators that were removed in step 2 on
page 509 of this procedure?
Yes
No
↓
Go to step 15 of this procedure.
This ends the procedure.
CACHBAT
The cache battery pack may be failing. Use the cache battery pack location
information in the Service Action Log if it is available. If the location is not
available, find the address of the storage IOA. See “SRC Address Formats” on
page 936. Use the address to find the location. See “Locations and Addresses” on
page 705.
If the failing item is in a migration tower, go to the CACHBAT symbolic FRU in
the
Migrated Expansion Tower Problem Analysis, Repair and Parts
.
Using the type number of the storage IOA, go to “Type, Model, and Part Number
list” on page 885 to determine the cache battery pack part number.
To exchange the cache battery pack, see “Type 2748, 2763, 2778 – Cache Battery
Pack” on page 684.
This ends the procedure.
CACHE
The cache adapter card is only a separate failing item on migrated towers. If the
cache adapter card is located in a migrated tower, see the CACHE symbolic FRU
in
Migrated Expansion Tower Problem Analysis, Repair and Parts
for FRU isolation
instructions.
This ends the procedure.
Symbolic FRUs
Chapter 3. Problem Isolation Procedures (PIPs), Failing Items, and Symbolic FRU Isolation
511
Summary of Contents for i 830
Page 2: ......
Page 14: ...xii iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 15: ...Part 1 Problem Analysis Copyright IBM Corp 2000 2001 1...
Page 16: ...2 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 628: ...Symbolic FRUs 614 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 629: ...Part 2 FRU Replacement Copyright IBM Corp 2000 2001 615...
Page 630: ...616 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 817: ...Part Assemblies Chapter 5 Locations Addresses and Part Listings 803...
Page 897: ...Miscellaneous Chapter 5 Locations Addresses and Part Listings 883...
Page 906: ...892 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 962: ...948 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 963: ...Part 3 Appendixes Copyright IBM Corp 2000 2001 949...
Page 964: ...950 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 968: ...954 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 970: ...956 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 974: ...960 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 980: ...966 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 982: ...968 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 984: ...970 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 986: ...972 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 990: ...976 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 999: ......