13.
The display that appears is showing the status of the HSL ports for the next
I/O Bridge resource on the loop. Go to step 9 on page 303 of this procedure.
14.
Find the information for the
failing HSL I/O Bridge
using the following steps:
a.
Record the resource name, card type-model, part number, and port.
b.
Select the
″
cancel
″
function to return to the
″
Work with high-speed link (HSL)
resources
″
display.
c.
Select the
″
Resources associated with loop
″
option for the loop with the
failure.
d.
Select the
″
Associated packaging resources
″
option for the HSL I/O Bridge
with the resource name that you recorded.
e.
Record the frame ID.
f.
Select the
″
Display detail
″
option and record the card position.
15.
Have you repeated steps 1 through 14 for a second time during this
procedure?
No
Yes
↓
Return to the procedure that sent you here.
This ends the procedure.
16.
The following steps guide you through disconnecting and reconnecting the
HSL cable connections on this HSL I/O Bridge to determine if the cable
connectors are properly seated and clean.
17.
Disconnect the cable labelled port 0 at the frame ID of the
HSL I/O bridge
.
18.
Is the connection an optical link?
No
Yes
↓
Clean the HSL cable connector and port using the tools and
procedures listed in symbolic FRU “OPT_CLN” on page 561. Go to
step 20 of this procedure.
19.
Wait at least 30 seconds.
20.
Reconnect the cable to the port.
Attention:
You must fully connect the cable and tighten the connector’s
screws within 30 seconds of when the cable makes contact with the port. If
you do not the link will fail and you must disconnect and reconnect again. If
the connector screws are not tightened errors will occur on the link and it will
fail.
21.
Disconnect the cable labelled port 1 at the frame ID of the
HSL I/O Bridge
.
22.
Is the connection an optical link?
No
Yes
↓
Clean the HSL cable connector and port using the tools and
procedures listed in symbolic FRU “OPT_CLN” on page 561. Go to
step 24 of this procedure.
23.
Wait at least 30 seconds.
24.
Reconnect the cable to the port.
Attention:
You must fully connect the cable and tighten the connector’s
screws within 30 seconds of when the cable makes contact with the port. If
you do not the link will fail and you must disconnect and reconnect again. If
the connector screws are not tightened errors will occur on the link and it will
fail.
25.
Refresh the port status by:
Bus, High-Speed Link (HSL) PIPs
304
iSeries Model 830, 840, SB2, and SB3 Problem Analysis, Repair and Parts V5R1
Summary of Contents for i 830
Page 2: ......
Page 14: ...xii iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 15: ...Part 1 Problem Analysis Copyright IBM Corp 2000 2001 1...
Page 16: ...2 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 628: ...Symbolic FRUs 614 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 629: ...Part 2 FRU Replacement Copyright IBM Corp 2000 2001 615...
Page 630: ...616 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 817: ...Part Assemblies Chapter 5 Locations Addresses and Part Listings 803...
Page 897: ...Miscellaneous Chapter 5 Locations Addresses and Part Listings 883...
Page 906: ...892 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 962: ...948 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 963: ...Part 3 Appendixes Copyright IBM Corp 2000 2001 949...
Page 964: ...950 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 968: ...954 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 970: ...956 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 974: ...960 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 980: ...966 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 982: ...968 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 984: ...970 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 986: ...972 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 990: ...976 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 999: ......