5.
Exchange the failing disk unit (see “Chapter 4. Removal and Installation
Procedures” on page 617). When finished, continue with the next step of this
procedure.
6.
Perform the following:
a.
Ask the customer to stop all active applications on the system and power
the system off with the
Power Down System (PWRDWNSYS)
command.
b.
Perform an IPL to DST (see “Dedicated Service Tools (DST)” in the
iSeries
Service Functions
information).
c.
Select the
Work with disk units
option.
d.
Select the
Work with disk unit recovery
option on the Work with Disk Units
display.
e.
Select the
Rebuild disk unit data
option.
f.
Select the disk unit on the display that was installed in place of the failing
disk unit.
g.
Rebuild the disk unit data. When the new disk unit is rebuilt, the display
shows that the status is complete (this may take 30 minutes or longer).
h.
Press the Enter key after verifying that the status is complete.
7.
Perform the following:
a.
Return to the Use Dedicated Service Tools (DST) display.
b.
Select the
Perform an IPL
option to complete the IPL.
8.
Return to the procedure that sent you here.
This ends the procedure.
Exchanging a Disk Unit with Mirrored Protection
Definitions:
v
Local load source - A disk used as the source for IPL data.
Primary Partition:
– For system models 270 and 820, this disk unit must be located in position
D01, D02, D03, or D04.
– For system models 830, 840, SB2 and SB3, this disk unit must be located in
position D31, D32, D33, or D34.
Secondary Partition:
– See ’Locating a Secondary Partition’s Load Source From the Primary
Partition’s Console’ in the
iSeries Service Functions
information
v
Remote load source - A load source disk unit that is not a local load source.
1.
Display the disk unit status by performing the following:
a.
Select system service tools (SST).
If you cannot get to SST, select dedicated service tools (DST) (see
“Accessing Dedicated Service Tools” in the
iSeries Service Functions
).
Note:
If the customer is running applications on the system, do not power
off the system or IPL the system to get to DST.
If you cannot get to SST or DST, and the system fails during the IPL
to DST, the local load source disk unit may be in the wrong location
or in a failed state. SRCB1xx4504 is displayed during the IPL to DST
if a functional load source disk unit is failing or not in one of the
positions indicated by the local load source definition above.
Data Recovery and General System Information
Chapter 6. Data Recovery Procedures and General System Information
897
Summary of Contents for i 830
Page 2: ......
Page 14: ...xii iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 15: ...Part 1 Problem Analysis Copyright IBM Corp 2000 2001 1...
Page 16: ...2 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 628: ...Symbolic FRUs 614 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 629: ...Part 2 FRU Replacement Copyright IBM Corp 2000 2001 615...
Page 630: ...616 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 817: ...Part Assemblies Chapter 5 Locations Addresses and Part Listings 803...
Page 897: ...Miscellaneous Chapter 5 Locations Addresses and Part Listings 883...
Page 906: ...892 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 962: ...948 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 963: ...Part 3 Appendixes Copyright IBM Corp 2000 2001 949...
Page 964: ...950 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 968: ...954 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 970: ...956 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 974: ...960 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 980: ...966 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 982: ...968 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 984: ...970 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 986: ...972 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 990: ...976 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 999: ......