d.
Select the Work with disk unit recovery option on the Work with Disk
Unit display.
e.
Select the Recover configuration option on the Work with Disk Unit
Recovery display. This option assembles the system configuration
information on disk unit 1 in the system unit.
Notes:
a.
A warning message appears stating that recovering the configuration
destroys all system data.
b.
If you have a system with only one disk unit, a message may appear
stating that your request to recover the configuration was not successful.
The recover configuration function cannot be performed on a system with
only one disk unit.
Continue with the next step of this procedure.
18.
The ASP to which the failing disk unit was assigned is cleared. The customer
should do the following:
v
If the disk unit you exchanged is in ASP 1, have the customer see the
Backup and Recovery information. You must restore the operating system
(OS/400 Licensed Program) and all customer data.
v
If the disk unit is in a user ASP (ASP 2 through ASP 16), data in the ASP is
lost. See the Backup and Recovery information.
This ends the procedure.
19.
Perform an IPL from removable media and restore the Licensed Internal Code
(see “Restoring Licensed Internal Code” in the
iSeries Service Functions
information). This information shows you how to perform an IPL and restore
the Licensed Internal Code.
Note:
Some objects may be damaged. The customer may have to load the
damaged objects again (see the
Backup and Recovery
information).
This ends the procedure.
20.
Is the failing unit missing from the configuration?
No
Yes
↓
Go to step 31 of this procedure.
21.
Find another disk unit on the system, other than the load-source disk unit.
22.
Perform the following to install a new disk unit on the system:
a.
Power off the system.
b.
Slide the disk unit you found in step 21 of this procedure out of the
system (see “Chapter 4. Removal and Installation Procedures” on
page 617).
c.
Be very careful with the disk unit. You will install it again when the repair
actions to the failing disk unit are complete.
d.
Install the new disk unit.
23.
Perform an IPL to DST (see “Dedicated Service Tools (DST)” in the
iSeries
Service Functions
information).
Does the Use Dedicated Service Tools (DST) display appear?
Yes
No
↓
Repeat step 1 of this procedure.
Data Recovery and General System Information
Chapter 6. Data Recovery Procedures and General System Information
915
Summary of Contents for i 830
Page 2: ......
Page 14: ...xii iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 15: ...Part 1 Problem Analysis Copyright IBM Corp 2000 2001 1...
Page 16: ...2 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 628: ...Symbolic FRUs 614 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 629: ...Part 2 FRU Replacement Copyright IBM Corp 2000 2001 615...
Page 630: ...616 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 817: ...Part Assemblies Chapter 5 Locations Addresses and Part Listings 803...
Page 897: ...Miscellaneous Chapter 5 Locations Addresses and Part Listings 883...
Page 906: ...892 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 962: ...948 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 963: ...Part 3 Appendixes Copyright IBM Corp 2000 2001 949...
Page 964: ...950 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 968: ...954 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 970: ...956 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 974: ...960 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 980: ...966 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 982: ...968 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 984: ...970 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 986: ...972 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 990: ...976 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 999: ......