18.
Is a function 11 SRC displayed on the system unit control panel?
No
Yes
↓
Go to “Starting Point for All Problems” on page 4.
This ends the procedure.
19.
Is the Power Ready light on continuously?
Note:
The Power Ready light blinks at a 1 second rate during a normal
power-on sequence. It should not blink for more than 1 minute.
No
Yes
↓
Go to step 21 of this procedure.
20.
Perform the following:
a.
d. Disconnect the mainline AC power cable from the customer’s AC power
outlet.
b.
Exchange one of the following FRUs:
v
SPCN card (TWRCARD)
v
AC module (ACMODUL) or Battery Charger unit (BATCHGR)
v
System unit control panel card (CTLPNL)
c.
Reconnect the mainline AC power cable to the power outlet.
d.
Attempt to power on the system.
e.
If the system powers on, the FRU you exchanged is the failing item.
If the system does not power on, repeat steps 20a through 20e of this
procedure and exchange the next FRU in the list. If the system does not power
on after exchanging all the FRUs in the list, ask your next level of support for
assistance.
This ends the procedure.
21.
Is there more than one frame on the system?
Yes
No
↓
Go to step 23 of this procedure.
22.
Do all of the frames on the system become powered on?
Yes
No
↓
Go to “Cannot Power On Secondary Frame or Unit (No SRC)”.
This ends the procedure.
23.
Continue the IPL. Does the IPL complete successfully?
No
Yes
↓
This ends the procedure.
24.
Go to “Starting Point for All Problems” on page 4.
This ends the procedure.
Cannot Power On Secondary Frame or Unit (No SRC)
You are here because of a secondary frame or unit that cannot become powered on
and may be displaying a 1xxx-C62E.
Power Problems
42
iSeries Model 830, 840, SB2, and SB3 Problem Analysis, Repair and Parts V5R1
Summary of Contents for i 830
Page 2: ......
Page 14: ...xii iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 15: ...Part 1 Problem Analysis Copyright IBM Corp 2000 2001 1...
Page 16: ...2 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 628: ...Symbolic FRUs 614 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 629: ...Part 2 FRU Replacement Copyright IBM Corp 2000 2001 615...
Page 630: ...616 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 817: ...Part Assemblies Chapter 5 Locations Addresses and Part Listings 803...
Page 897: ...Miscellaneous Chapter 5 Locations Addresses and Part Listings 883...
Page 906: ...892 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 962: ...948 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 963: ...Part 3 Appendixes Copyright IBM Corp 2000 2001 949...
Page 964: ...950 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 968: ...954 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 970: ...956 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 974: ...960 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 980: ...966 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 982: ...968 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 984: ...970 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 986: ...972 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 990: ...976 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 999: ......