27.
Wait 1 minute to allow the changes to be detected by LIC.
28.
Determine if the link has become
″
operational
″
by repeating steps 2 through 15
of this procedure for a
second
time. There is no need to duplicate any
information you have already recorded.
Return to the procedure that sent you here, when you are directed to do so in
steps 2 through 15 of this procedure.
This ends the procedure.
BUS PIP HSL-03
Bus PIP HSL-03, Use HSM to examine the HSL Loop to find
failing
items.
This procedure will direct you to use HSM screens to determine the status of HSL
links in the loop.
1.
Sign on to SST or DST.
2.
Select the
Start a service tool
option.
3.
Select the
Hardware sevice manager
option.
4.
Select the
Logical hardware resources
option.
5.
Select the
System interconnect
option.
6.
Move the cursor to the HSL loop that you are here to examine. Select the
Display detail
option.
7.
Select the function
Include non-reporting resources
.
8.
The display that appears is showing the port status of the HSL controller for
the loop that you selected. Record the resource name, type-model, and serial
number, if it has not been previously recorded.
9.
Is the status of the
″
Leading port to next resource
″″
operational
?
Yes
No
↓
You have found the first
″
failed
″
resource in the link. You will be
directed to find the other
″
failed
″
resource on this link. Go to step 14 of
this procedure.
10.
Select function
″
Follow leading port
″
.
11.
Record the HSL resource name, type-model, part number, and port.
12.
Is the resource name the same name that you recorded for the HSL controller
in step 8 of this procedure?
No
Yes
↓
You have followed the HSL links around the loop and back to the
HSL controller on the system. You did not find a
″
failed
″
link. Return
to the procedure that sent you here.
This ends the procedure.
13.
The display that appears is showing the status of the HSL ports for the next
I/O adapter resource on the loop. Go to step 9 of this procedure.
14.
Find the information for the
″
first
″
failing resource using the following steps:
a.
Record the information as the
″
first
″
failing resource on the link.
b.
Record the resource name, card type-model, part number, and port.
c.
Select the
″
cancel
″
function to return to the
″
Work with system interconnect
resources
″
display.
d.
Select the
Resources associated with ring
option for the loop with the failure.
Bus, High-Speed Link (HSL) PIPs
Chapter 3. Problem Isolation Procedures (PIPs), Failing Items, and Symbolic FRU Isolation
301
Summary of Contents for i 830
Page 2: ......
Page 14: ...xii iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 15: ...Part 1 Problem Analysis Copyright IBM Corp 2000 2001 1...
Page 16: ...2 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 628: ...Symbolic FRUs 614 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 629: ...Part 2 FRU Replacement Copyright IBM Corp 2000 2001 615...
Page 630: ...616 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 817: ...Part Assemblies Chapter 5 Locations Addresses and Part Listings 803...
Page 897: ...Miscellaneous Chapter 5 Locations Addresses and Part Listings 883...
Page 906: ...892 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 962: ...948 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 963: ...Part 3 Appendixes Copyright IBM Corp 2000 2001 949...
Page 964: ...950 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 968: ...954 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 970: ...956 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 974: ...960 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 980: ...966 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 982: ...968 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 984: ...970 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 986: ...972 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 990: ...976 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 999: ......