Yes
No
↓
Exchange the power control compartment, AC module, or SPCN card
(BKSPCN or TWRCARD) in the frame from which you removed the
SPCN optical adapter. See the removal and installation procedures in
this book or in the
Migrated Expansion Tower Problem Analysis, Repair
and Parts
, depending on the secondary frame you are working on.
This ends the procedure.
26.
Exchange the following FRUs, one at a time. (See the removal and installation
procedures in this book or in the
Migrated Expansion Tower Problem Analysis,
Repair and Parts
, depending on the secondary frame you are working on.
v
PCC in the failing frame (first frame with a failure indication)
v
PCC, AC module, or SPCN card (BKSPCN or TWRCARD) in the preceding
frame in the string
v
SPCN optical adapter A in the preceding frame in the string
v
SPCN optical adapter B in the failing frame
v
SPCN optical cables C between the preceding frame in the string and the
failing frame.
(A) SPCN
Optical
┌───── (C) SPCN
Adapter ────┐
│
Optical Cables
│
│
│
│
┌─── (B) SPCN
┌─────────┐
│
│
│
Optical
│ System │
│
│
│
Adapter
│ Unit
│
:
│
:
│
J15
│
┌─┐
:
┌─┐
└────┬────┘
│ ├────────────┤ │
│
│ ├────────────┤ │
┌────┴────┐ ┌───────┴─┤
┌───────┴─┤ ┌─────────┐
│
J15
│ │
J16│
│
J15│ │
│
│Frame J16├─┤J15 Frame│
│Frame J16├─┤J15 Frame│
│ 1
│ │
2 │
│ 3
│ │
4 │
└─────────┘ └─────────┘
└─────────┘ └─────────┘
G
│
│
└───Failing Frame
This ends the procedure.
27.
Perform the following:
a.
Power off the system.
b.
Disconnect the SPCN frame-to-frame cable from J15 on the PCC of the first
secondary frame that cannot become powered on.
c.
Connect the negative lead of a multimeter to the system frame ground.
d.
Connect the positive lead of the multimeter to pin 2 of the SPCN cable.
Note:
Use an insulated probe or jumper when performing the voltage
readings.
e.
Note the voltage reading on pin 2.
f.
Move the positive lead of the multimeter to pin 3 of the SPCN cable.
Power Problems
Chapter 1. Starting Problem Analysis
47
Summary of Contents for i 830
Page 2: ......
Page 14: ...xii iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 15: ...Part 1 Problem Analysis Copyright IBM Corp 2000 2001 1...
Page 16: ...2 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 628: ...Symbolic FRUs 614 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 629: ...Part 2 FRU Replacement Copyright IBM Corp 2000 2001 615...
Page 630: ...616 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 817: ...Part Assemblies Chapter 5 Locations Addresses and Part Listings 803...
Page 897: ...Miscellaneous Chapter 5 Locations Addresses and Part Listings 883...
Page 906: ...892 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 962: ...948 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 963: ...Part 3 Appendixes Copyright IBM Corp 2000 2001 949...
Page 964: ...950 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 968: ...954 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 970: ...956 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 974: ...960 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 980: ...966 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 982: ...968 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 984: ...970 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 986: ...972 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 990: ...976 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 999: ......