c.
Select the
Refresh
function.
d.
Move to the
″
Display HSL Information
″
screen for the
first
failing resource.
53.
For the
first
failing resource, did the failing port number change?
No
Yes
↓
Exchange the HSL I/O Bridge in the frame of the first failing resource
(see “SIIOADP” on page 585). Then go to step 79 on page 298 of this
procedure.
54.
Is the HSL cable an optical HSL cable?
Yes
No
↓
Go to step 56 of this procedure.
55.
Examine the state of the LEDs associated with the optical ports where the
HSL cable connections are by performing the following: Determine which
LEDs to examine using the table below.
Table 13. LED Locations
Frame type
LED locations
FC 5074, 5078/0578
LEDs are located on the HSL I/O Bridge
card directly below the optical ports for the
HSL cable. There is one (1) LED associated
with each port and they are labeled as
x
-1L,
x
-2L,
y
-1L,
y
-2L, where
x
and
y
are the port
numbers.
Models 830/SB2
LEDs are located in pairs directly below the
optical ports for the HSL cable. There is one
(1) LED associated with each port and they
are labeled as
B0-1L
,
B0-2L
,
B1-1L
,
B1-2L
.
See Figure 33 on page 717.
Models 840/SB3
LEDs are located in pairs either above or
below the optical ports. The two (2) LEDs
closest to (above or below) the optical port
pair for the cable belong to that port pair.
There is one (1) LED associated with each
port and they are labeled as
x
-1L,
x
-2L,
y
-1L,
y
-2L, where
x
equal D0 or E0 and
y
equals
D1 or E1.
See Figure 40 on page 733.
Examine both LEDs at the ports for each end of the optical cable. Are all four
(4) LEDs lighted?
No
Yes
↓
Go to step 58 of this procedure.
56.
Exchange the HSL cable (see “SIRGCBL” on page 588).
57.
Is the leading port status of the HSL link from the
first
failing resource
″
failed
″
?
Yes
No
↓
The link is now functioning. Go to step 79 on page 298 of this
procedure.
58.
Exchange these FRUs in the following order:
Bus, High-Speed Link (HSL) PIPs
Chapter 3. Problem Isolation Procedures (PIPs), Failing Items, and Symbolic FRU Isolation
295
Summary of Contents for i 830
Page 2: ......
Page 14: ...xii iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 15: ...Part 1 Problem Analysis Copyright IBM Corp 2000 2001 1...
Page 16: ...2 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 628: ...Symbolic FRUs 614 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 629: ...Part 2 FRU Replacement Copyright IBM Corp 2000 2001 615...
Page 630: ...616 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 817: ...Part Assemblies Chapter 5 Locations Addresses and Part Listings 803...
Page 897: ...Miscellaneous Chapter 5 Locations Addresses and Part Listings 883...
Page 906: ...892 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 962: ...948 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 963: ...Part 3 Appendixes Copyright IBM Corp 2000 2001 949...
Page 964: ...950 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 968: ...954 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 970: ...956 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 974: ...960 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 980: ...966 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 982: ...968 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...