Reference
Code
Description/Action Perform all actions before exchanging
Failing Items
Failing Item
Location
69C8
Abnormal or unexpected HSL OptiConnect disconnection from
a remote system or partition.
The local system or partition disconnected from a remote
system or partition due to an unexpected event or failure. All of
the HSL OptiConnect connections on this loop will be in a
failed state. LIC will attempt to recover from the error.
Intervention at the local or remote system or partition may be
required. Possible causes are:
v
time out of a critical message
v
LIC code / table problem
v
Network deadlock detected
The problem may be with:
v
The local system or partition
v
The remote system or partition
Examine the Service Action Log (SAL) on the local system or
partition for HSL failures on the same HSL loop, or with the
Network Interface Controller at approximately the same time
this error occurred.
Examine the remote system or partition for problems. Examine
the Service Action Log (SAL) on the remote system or partition
for problems on the same HSL loop or with the Network
Interface Controller at approximately the same time this error
occurred.
Correct any problems you find with the remote and local
systems or partitions that happened at approximately the same
time and involve HSL Opticonnect or HSL loop components or
Network Interface Controllers.
If there are no problems with the remote system or partition
and there are no problems with the local system or partition
then collect all the Product Activity Log information for this
failure on all systems or partitions. Be sure to record all words
in the SRCs. Contact your next level of support.
REM_SYS
LOC_SYS
AJDG301
B6xx (including A6xx)
Chapter 2. Unit Reference Codes
269
Summary of Contents for i 830
Page 2: ......
Page 14: ...xii iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 15: ...Part 1 Problem Analysis Copyright IBM Corp 2000 2001 1...
Page 16: ...2 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 628: ...Symbolic FRUs 614 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 629: ...Part 2 FRU Replacement Copyright IBM Corp 2000 2001 615...
Page 630: ...616 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 817: ...Part Assemblies Chapter 5 Locations Addresses and Part Listings 803...
Page 897: ...Miscellaneous Chapter 5 Locations Addresses and Part Listings 883...
Page 906: ...892 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 962: ...948 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 963: ...Part 3 Appendixes Copyright IBM Corp 2000 2001 949...
Page 964: ...950 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 968: ...954 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 970: ...956 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 974: ...960 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 980: ...966 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 982: ...968 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 984: ...970 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 986: ...972 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 990: ...976 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 999: ......