Then, go to “Chapter 2. Unit Reference Codes” on page 59 and use the
SRC information to correct the problem.
This ends the procedure
.
11.
Contact your next level of support.
This ends the procedure
.
Logical Partition Hangs or Loops (No SRC)
This procedure is for the case where the hanging or looping partition does not
display an SRC in the Primary partition’s
Work with Partition Status
screen.
You are here because:
v
Logical partition operation is hung (very low processor activity indicated on the
control panel with workstation(s) input inhibited).
v
Logical partition operation is in a loop (very high processor activity indicated on
the control panel with workstation(s) input inhibited).
A logical partition hang or loop is the result of either:
v
A software failure.
v
Software improperly handling a hardware failure.
This procedure assumes that the logical partition completed an IPL and that at
least one user had successfully signed on before the condition occurred.
The purpose of this procedure is to:
1.
Help you report the problem with enough error data to permit an APAR
investigation to resolve the software problem.
2.
Provide you with direction to identify any possible hardware failure.
Perform the following:
1.
Is the logical partition operational from
any
workstation?
No
Yes
↓
Work with the system operator to complete the appropriate problem
handling procedures. See:
v
The Information Center at
http://www.ibm.com/eserver/iseries/infocenter
This ends the procedure
.
2.
Perform steps 2a through 2i on page 35 on the system’s physical panel and
NOT
on the
Partition Status
screen in the Primary partition. Collect and record
the failure data (see the
iSeries Service Functions
).
Note:
If any of the data collection steps fail, go to step 4 of this procedure.
a.
Select Manual mode (see
iSeries Service Functions
).
b.
Select Function 25 on the control panel and press the Enter key.
c.
Select Function 26 on the control panel and press the Enter key.
d.
Select Function 50 on the control panel and press the Enter key to
stop the system. After a short time, SRC D141900F displays and
indicates the system is stopped.
e.
Select Function 51 on the control panel and press the Enter key. The
display shows 51**.
IPL Problems
34
iSeries Model 830, 840, SB2, and SB3 Problem Analysis, Repair and Parts V5R1
Summary of Contents for i 830
Page 2: ......
Page 14: ...xii iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 15: ...Part 1 Problem Analysis Copyright IBM Corp 2000 2001 1...
Page 16: ...2 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 628: ...Symbolic FRUs 614 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 629: ...Part 2 FRU Replacement Copyright IBM Corp 2000 2001 615...
Page 630: ...616 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 817: ...Part Assemblies Chapter 5 Locations Addresses and Part Listings 803...
Page 897: ...Miscellaneous Chapter 5 Locations Addresses and Part Listings 883...
Page 906: ...892 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 962: ...948 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 963: ...Part 3 Appendixes Copyright IBM Corp 2000 2001 949...
Page 964: ...950 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 968: ...954 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 970: ...956 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 974: ...960 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 980: ...966 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 982: ...968 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 984: ...970 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 986: ...972 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 990: ...976 iSeries Model 830 840 SB2 and SB3 Problem Analysis Repair and Parts V5R1...
Page 999: ......