4-12
Field
Description
DEVICE_SERIAL_NUMBER Device
serial
number
MAC_ADDRESS
MAC address of the device
MANUFACTURING_DATE
Manufacturing date of the device
VENDOR_NAME Vendor
name
display environment
Syntax
display environment
View
Any view
Default Level
1: Monitor level
Parameters
None
Description
Use the
display environment
command to display the temperature information, including the current
temperature and temperature thresholds of boards.
Examples
# Display the temperature information of the device.
<Sysname> display environment
System Temperature information (degree centigrade):
----------------------------------------------------
SlotNo Temperature Lower limit Upper limit
1 34 0 55
2 34 0 55
Table 4-5 display environment
command output description
Field
Description
System Temperature information (degree
centigrade)
Temperature information of system boards
(degree centigrade)
SlotNO
Member ID of the device
Temperature Current
temperature
Lower limit
Lower limit of temperature
Upper limit
Upper limit of temperature
Summary of Contents for E4510-48G
Page 109: ...2 18 Sysname interface bridge aggregation 1 Sysname Bridge Aggregation1 shutdown ...
Page 309: ...6 4 Sysname interface vlan interface 1 Sysname Vlan interface1 ip address dhcp alloc ...
Page 324: ...8 3 Sysname interface vlan interface 1 Sysname Vlan interface1 ip address bootp alloc ...
Page 530: ...2 5 Sysname mvlan 100 subvlan 10 to 15 ...
Page 739: ...8 15 Sysname system view Sysname port security trap addresslearned ...
Page 819: ...13 11 Sysname system view Sysname public key peer key2 import sshkey key pub ...
Page 914: ...5 17 Sysname reset oam ...
Page 1064: ...5 30 Slot 2 Set next configuration file successfully ...
Page 1325: ...21 13 Examples Redirect to member 2 Sysname irf switch to 2 Sysname Slave 2 ...