Figure 158:
System > Performance
Page Illustration (Partial Screen)
Field
Description
System Information
CPU(s)
Basic CPU information as reported by the operating system.
Memory
The amount of physical RAM and Swap space seen by the operating system. Refer to the
Dell
PowerConnect W-AirWave Sizing Guide
at dell.com/support/manuals for hardware
requirements.
Kernel
The version of the Linux kernel running on the box.
Architecture
The AirWave’s architecture information.
Device Polling
Displays some AP/Device polling statistics.
Performance Graphs
System Load Average
The number of jobs currently waiting to be processed. Load is a rough metric that will tell
you how busy a server is. A typical AirWave load is around 2-3 times the number of CPU
cores you have in your system. A constant load of 4x to 5x is cause for concern. A load above
Table 122:
System > Performance Page Fields and Graphs
Dell PowerConnect W-AirWave 7.6 | User Guide
Performing Daily Administration in AirWave | 227
Summary of Contents for PowerConnect W-AirWave 7.6
Page 1: ...Dell PowerConnect W AirWave 7 6 User Guide ...
Page 12: ...xii Dell PowerConnect W AirWave 7 6 User Guide ...
Page 112: ...100 Configuring and Using Device Groups Dell PowerConnect W AirWave 7 6 User Guide ...
Page 162: ...150 Discovering Adding and Managing Devices Dell PowerConnect W AirWave 7 6 User Guide ...
Page 198: ...186 Using RAPIDS and Rogue Classification Dell PowerConnect W AirWave 7 6 User Guide ...
Page 276: ...264 Creating Running and Emailing Reports Dell PowerConnect W AirWave 7 6 User Guide ...
Page 324: ...312 Using VisualRF Dell PowerConnect W AirWave 7 6 User Guide ...
Page 332: ...320 Index Dell PowerConnect W AirWave 7 6 User Guide ...