5000 Series Layer 2/3 Managed Data Center Switch CLI Reference Guide
286
Voltage
Internally measured supply voltage.
Current
Measured TX bias current.
Output Power
Measured optical output power relative to 1mW.
Input Power
Measured optical power received relative to 1mW.
TX Fault
Transmitter fault.
LOS
Loss of signal.
5-188 show fiber-ports optical-transceiver-info
Display SFP vendor-related information. The values are derived from the SFP’s A0 table using the l
2
C
interface.
show fiber-ports optical-transceiver-info {all | slot/port}
Parameters
All
Enter all for all interfaces.
slot/port
Enter an interface in slot/port format.
Default
The default is None.
Command Mode
Privileged EXEC
Example
The following is a CLI display output example.
(Switching)#show fiber-ports optical-transceiver-info all
Port
Vendor Name
Link Length 50um [m] Link Length 62.5 um [m]
-----
---------------- -------------------- -----------------------
0/49
DQS-5000-54SQ28
8
3
0/51
DQS-5000-54SQ28
8
3
0/52
DQS-5000-54SQ28
8
3
Serial Number
Part Number Nominal Bit Rate [Mbps]
Rev
-------------
----------- ----------------------
-----
A7N2018414
AXM761
10300
10
A7N2018472
AXM761
10300
10
A7N2018501
AXM761
10300
10
(Switching)#show fiber-ports optical-transceiver-info 0/49