5000 Series Layer 2/3 Managed Data Center Switch CLI Reference Guide
199
5-65
logging email test message-type
This command is used to send an email to the SMTP server in order to test the email alert function.
logging email test message-type {urgent | non-urgent | both} message-body msg-body
Parameters
both
Indicates both urgent and non urgent message types.
non-urgent
Indicates non urgent message types.
urgent
Indicates urgent message types.
message-body msg-body
Indicates the message string for the email body of the alert message.
None
Default
The default is No default value.
Command Mode
Global Config
5-66
show logging email config
This command is used to show information about the configuration.
show logging email config
Parameters
None
Default
The default is None.
Command Mode
Privileged EXEC
Example
The following shows an example of the command.
(Routing)#show logging email config
Email Alert Logging.............................. disabled