5000 Series Layer 2/3 Managed Data Center Switch CLI Reference Guide
649
Configure the link layer encapsulation type for the packet on an interface or range of interfaces. The
encapsulation type can be
ethernet
or
snap
.
Note:
Routed frames are always ethernet encapsulated when a frame is routed to a VLAN.
encapsulation {ethernet | snap}
Parameters
ethernet
Enter an Ethernet encapsulation type.
snap
Enter an Subnetwork Access Protocol type.
Default
The default is Ethernet.
Command Mode
Interface Config
7-32
show dhcp lease
Display a list of IPv4 addresses currently leased from a D
HCP server on a specific in-band interface or all
in-band interfaces. Does not apply to service or network ports.
show dhcp lease [interface {slot/port | vlan id}]
Parameters
slot/port
Enter an interface in slot/port format.
vlan id
Enter an interface in VLAN format.
Default
The default is None.
Command Mode
Privileged EXEC
Example
The following is an example of the CLI display output for the command.
(Routing)#show dhcp lease
IP address: 10.10.1.1 for peer on Interface: FastEthernet0/0
Subnet mask: 255.255.255.0
DHCP Lease server: 10.10.1.2, state: 3 Bound
DHCP transaction id: 93
Lease: 86400 secs, Renewal: 43200 secs, Rebind: 75600 secs