5000 Series Layer 2/3 Managed Data Center Switch CLI Reference Guide
292
Default
The default is None.
Command Mode
Privileged EXEC
Example
The following is a CLI display output example.
(Routing)#show rmon alarms
Index
OID
Owner
-------
-----------------
-------------
1
alarmInterval.1
MibBrowser
2
alarmInterval.1
MibBrowser
The following is a CLI display output example.
(Routing)#show rmon alarm 1
Alarm 1
---------------
OID: alarminterval 1
Last Sample Value: 1
Interval: 1
Sample Type: absolute
Startup Alarm: rising-falling
Rising Threshold: 1
Falling Threshold: 1
Rising Event: 1
Falling Event: 2
Owner: DLBrowser
Display Parameters
Alarm
Unique index identifying an entry in the alarm table. Each entry defines
a diagnostic sample at a particular interval for an object on the device.
The range is 1 to 65535.
OID
Object ID to which the variable name is resolved. The format is x.x.x.x.
Last Sample Value
Object ID of the last event.
Interval
Interval (seconds) defining rising and falling thresholds sampling and
comparison period. The range is 1 to 2147483647. The default is 1.
Sample Type Absolute
Statistical value during the last sampling period. This object is a read-
only, 32-bit signed value.
Startup Alarm
Specified alarm to send. Possible values are
rising
,
falling
or both
rising-falling
. The default is
rising-falling
.
Rising Threshold
Rising threshold for the statistical sample. The range is 2147483648 to
2147483647. The default is 1.