5000 Series Layer 2/3 Managed Data Center Switch CLI Reference Guide
628
Display Parameters
Tenant ID
Virtual Subnet ID (VSID).
Tenant MAC
MAC address of a host or tenant system.
VTEP
IP address of the VTEP if the tenant system is behind the remote VTEP.
This is valid for the remote tenant system, otherwise it is blank.
Interface
Access interface on which the MAC entry is learned or configured. This
valid for the tenant system on the local access interface, otherwise it is
blank.
Applflndex
lnternal access or tunnel port handle.
Entry Type
Configured or learned.
6-59
show vxlan vtep
This command is used to show the status of the remote VTEPs included in a given VXLAN virtual network.
show vxlan vnid vtep [ip-address]
Parameters
vnid
Indicates VXLAN VNID.
ip-address
(Optional) Indicates an IP address identifier of tenant system.
Default
The default is None.
Command Mode
Privileged EXEC
Example
(Routing)(Config)#show vxlan 1 vtep
Remote VTEP
Dest UDP Port
Uptime (sec)
Reachable
Reachable Transitions
--------------- --------------- ------------
---------
----------------------
20.20.20.1
4789
0
NO
0
200.200.200.1
4789
0
NO
0
(Routing)(ConFig)#show vxlan 1 vtep 20.20.20.1
VXLAN ID......................................... 1
Remote VTEP...................................... 20.20.20.1
Destination UDP Port............................. 4789
Reachable........................................ NO