7-89
Cisco TelePresence System Release 1.6 Administration Guide
OL-13676-04
Chapter 7 Troubleshooting the CTS 1300
Managing Hardware Setup
Step 6
Note the field of view for each camera.
Step 7
Using non-marking tape (for example, masking tape), tape a mark on the table that denotes the edge of
the field of view for each camera.
Place this mark approximately 18 inches (46 cm) from the edge of the table, and point the line of tape at
the camera.
Tip
If you cannot determine the camera range, use this guide for marking the table: The focal range of the
center segment is approximately 5 feet (152 cm) wide from where the participants sit. The focal range
of each side segment is approximately 4 feet six inches (137 cm) wide.
Mark the table in four places:
•
Edge of camera view, left camera
•
Edge of view between left and center camera
•
Edge of view between center and right camera
•
Edge of camera view, right camera
Note
If your table is narrow (for example, if you use a square or round table), omit the two markings on the
outer edges.