7-67
Cisco TelePresence System Release 1.6 Administration Guide
OL-13676-04
Chapter 7 Troubleshooting the CTS 1300
Managing Hardware Setup
Figure 7-62
Horizontal Bars and Focusing Targets
When the bars are roughly the same length, the camera is focused.
e.
Without moving the focus ring, tighten its thumbscrew.
Step 7
Click Done to complete the procedure.
Focusing the Left Camera
To focus the left camera, complete the steps in the following procedure.
Note
If you logged out of the GUI, you must re-select the correct table type after you log in; otherwise, you
could configure your system for the incorrect table type. To select the correct table type, complete
Step 5
in the
“Positioning the Table and Starting the Calibration Procedure” section on page 7-51
.
Step 1
In the Cisco TelePresence administrative GUI, click the Right radio button.
Step 2
Click the Setup button that is located below the center screen icon.
Step 3
Click Show Focus Targets.
Step 4
Position the small camera target by completing the following steps:
a.
Place the target on the table approximately one foot (30 cm) from the edge where the participants sit.
b.
Position the target so that the top two patterns on the target are enclosed in the green box.
Step 5
Position the large target by completing the following steps:
a.
Remove the large focus target from the easel.
b.
Rotate the target 90 degrees.
c.
Have another person hold the target upright.
Note
If another person is not available, clamp the top of the target into the clamp at the top of the easel.
d.
Place the top of the easel five feet (1.5 meters) behind the top of the small target.
206362
Red
rectangle
Green
rectangle
Large
target
Small
target
Red and green
horizontal bars