7-77
Cisco TelePresence System Release 1.6 Administration Guide
OL-13676-04
Chapter 7 Troubleshooting the CTS 1300
Managing Hardware Setup
See
Figure 7-54
for the location of the right target. The positioning for a square table is the same as the
positioning for a round table.
Position the target to that it is parallel with the wall.
Step 2
In the Cisco TelePresence administrative GUI, click the Right radio button.
Step 3
Click Show Camera Target.
Step 4
Focus the right camera by completing the following steps:
a.
Loosen the focus ring thumbscrew on the lens of the center camera.
b.
Rotate the focus ring until the black plus sign on the target is clearly in focus.
Note
The camera lens has two adjustment rings, one for focus and one for zoom. The focus ring is on
the inside.
Figure 7-71
Location of Focus and Zoom Ring
Focus ring
Zoom ring
206131