7-52
Cisco TelePresence System Release 1.6 Administration Guide
OL-13676-04
Chapter 7 Troubleshooting the CTS 1300
Managing Hardware Setup
Step 1
Position the table so that there is a minimum of 44 inches between the display and the front of the table,
and make sure that the sides of the table are evenly positioned on each side of the CTS 1300.
In addition, make sure that the farthest edge of the table is no farther than 10 feet (3 meters) away from
the lower bezel of the display.
Note
The table must be 28 to 32 inches high; 30 inches is the optimal height.
Figure 7-48
Round Table Positioning
Step 2
Make sure that the camera assembly is level by completing the steps in the
“Removing the Camera Cover
and Leveling the Cameras” section on page 7-8
.
Step 3
Build the easel, and attach the large camera target to the easel, by completing the steps in the
“Attaching
the Large Camera Target to the Easel” section on page 7-11
, making sure that the bottom of the target is
32 inches above the ground.
Step 4
Using a supported Internet browser, log in to the Cisco TelePresence System administration GUI.
Step 5
Select the correct table type by completing the following steps:
a.
Navigate to Troubleshooting > Hardware Setup > Configuration.
b.
Click the Start button to start testing.
c.
Select the Round Table drop-down choice.
Figure 7-49
shows the table configuration menu. Be sure to choose the correct table type.
A
B
A=B
44 inches
(112 cm)
minimum
8 feet (254 cm) minimum,
12 feet (366 cm) maximum)
206164
7 feet
(2.1 meters)
30 inches (76 cm)
between participants