Chapter 16
16-9
CRG-BS-M
Charging bias setting value (M)
[When used]
Low/high image density or fogging occurs but the problem cannot be solved by changing the density setting and performing special printing process.
[Adjustment method]
- When fogging occurs, it may be eliminated by increasing the setting value.
- Increase the setting value to slightly lower the image density.
- Decrease the setting value to slightly increase the image density.
Setting range: -10 to 10 (Unit: 20V)
[Factory setting value/Value after RAM clearing: 0]
CRG-BS-C
Charging bias setting value (C)
[When used]
Low/high image density or fogging occurs but the problem cannot be solved by changing the density setting and performing special printing process.
[Adjustment method]
- When fogging occurs, it may be eliminated by increasing the setting value.
- Increase the setting value to slightly lower the image density.
- Decrease the setting value to slightly increase the image density.
Setting range: -10 to 10 (Unit: 20V)
[Factory setting value/Value after RAM clearing: 0]
CRG-BS-K
Charging bias setting value (Bk)
[When used]
Low/high image density or fogging occurs but the problem cannot be solved by changing the density setting and performing special printing process.
[Adjustment method]
- When fogging occurs, it may be eliminated by increasing the setting value.
- Increase the setting value to slightly lower the image density.
- Decrease the setting value to slightly increase the image density.
Setting range: -10 to 10 (Unit: 20V)
[Factory setting value/Value after RAM clearing: 0]
DEV-BS-Y
Developing bias setting value (Y)
[When used]
Low/high image density or fogging occurs but the problem cannot be eliminated by changing the density setting and performing special printing
process.
[Adjustment method]
- Increase the setting value to increase the image density.
- Decrease the setting value to decrease the image density.
- When fogging occurs, it may be eliminated by decreasing the setting value.
Setting range: -10 to 10 (Unit: 20V)
[Factory setting value/Value after RAM clearing: 0]
DEV-BS-M
Developing bias setting value (M)
[When used]
Low/high image density or fogging occurs but the problem cannot be eliminated by changing the density setting and performing special printing
process.
[Adjustment method]
- Increase the setting value to increase the image density.
- Decrease the setting value to decrease the image density.
- When fogging occurs, it may be eliminated by decreasing the setting value.
Setting range: -10 to 10 (Unit: 20V)
[Factory setting value/Value after RAM clearing: 0]
DEV-BS-C
Developing bias setting value (C)
[When used]
Low/high image density or fogging occurs but the problem cannot be eliminated by changing the density setting and performing special printing
process.
[Adjustment method]
- Increase the setting value to increase the image density.
- Decrease the setting value to decrease the image density.
- When fogging occurs, it may be eliminated by decreasing the setting value.
Setting range: -10 to 10 (Unit: 20V)
[Factory setting value/Value after RAM clearing: 0]
DEV-BS-K
Developing bias setting value (Bk)
[When used]
Low/high image density or fogging occurs but the problem cannot be eliminated by changing the density setting and performing special printing
process.
[Adjustment method]
- Increase the setting value to increase the image density.
- Decrease the setting value to decrease the image density.
- When fogging occurs, it may be eliminated by decreasing the setting value.
Setting range: -10 to 10 (Unit: 20V)
[Factory setting value/Value after RAM clearing: 0]
FRT-TS-Y
Transfer bias front side setting value (Y)
[When used]
An image failure occurs depending on the type or condition of the paper AND the problem cannot be eliminated by performing special printing
process.
[Adjustment method]
- The problem may be eliminated by changing the setting value.
- Increase the setting value. (Effective for toner scatter/dotted image)
- Decrease the setting value. (Effective for white dots/white flower patches/image with high granularity in halftone mode)
Setting range: -30 to 40 (Unit: 50V)
- It is preferable to enter values in the condition of "M <= C <= Y <= K".
[Factory setting value/Value after RAM clearing: 0]
COPIER > ADJUST > VIFADJ
Sub item
Description
Summary of Contents for imageCLASS MF8450c
Page 16: ...Chapter 1 Introduction ...
Page 55: ...Chapter 2 Basic Operation ...
Page 61: ...Chapter 3 Main Controller ...
Page 75: ...Chapter 4 Original Exposure System ...
Page 88: ...Chapter 5 Original Feeding System ...
Page 105: ...Chapter 6 Laser Exposure ...
Page 113: ...Chapter 7 Image Formation ...
Page 150: ...Chapter 8 Pickup and Feed System ...
Page 184: ...Chapter 9 Fixing System ...
Page 200: ...Chapter 10 External and Controls ...
Page 230: ...Chapter 11 Maintenance and Inspection ...
Page 233: ...Chapter 12 Measurement and Adjustments ...
Page 237: ...Chapter 13 Correcting Faulty Images ...
Page 260: ...Chapter 14 Error Code ...
Page 272: ...Chapter 15 Special Management Mode ...
Page 280: ...Chapter 16 Service Mode ...
Page 322: ...Chapter 17 Upgrading ...
Page 327: ...Chapter 17 17 4 3 Click Next F 17 4 4 Select a USB connected device and click Next F 17 5 ...
Page 328: ...Chapter 17 17 5 5 Click Start F 17 6 6 Click Yes F 17 7 Download will be started F 17 8 ...
Page 330: ...Chapter 18 Service Tools ...
Page 334: ...Appendix ...
Page 349: ......