940
Brocade Network Advisor SAN User Manual
53-1003154-01
FCIP trunking
22
•
A valid failover group requires at least one metric 0 circuit and at least one metric 1 circuit. If
you do not configure these, a warning will display. If there is no metric 0 circuit and only a
metric 1 circuit, the metric 1 circuit will be used, regardless of whether there are metric 0
circuits in another failover group.
•
The number of valid failover groups defined per tunnel is limited by the number of circuits that
you can create for the switch model. For an 8 Gbps Extension Blade, you can configure up to 5
valid groups on an 10-circuit tunnel. On an 8 Gbps Extension Switch, you could have up to 3
valid groups because you can only configure 6 circuits per tunnel.
•
Consider available WAN bandwidth requirements when configuring failover circuit groups.
Refer to
“Bandwidth calculation during failover”
on page 938.
Examples of circuit failover in groups
Tables
Table 72
through
Table 74
provide examples of how failover occurs on circuits with different
bandwidths configured in failover groups.
Table 72
illustrates circuit failover in a tunnel with two failover groups, each with two circuits. All
data through the tunnel is initially load balanced over Circuits 1 and 2. The following occurs during
circuit failover:
•
If circuit 1 fails, circuit 3 becomes active and data is load balanced over circuit 2 and 3.
•
If circuit 2 fails, circuit 4 becomes active and data is load balanced over circuit 1 and 4.
•
If both circuit 1 and 2 fail, circuit 3 and.4 become active and data is load balanced over both
circuits.
Table 73
illustrates circuit failover in a tunnel with one failover group containing three circuits, In
this case, failover occurs as if circuits are not part of a failover group. Circuit 2 and 3, both with
metric 1, become active only after circuit 1 with metric 0 fails.
TABLE 72
Tunnel with two failover groups with two circuits
Circuits in tunnel
Failover group ID
Circuit bandwidth
In use for tunnel data
Circuit 1
Metric 0
1
500Mb
If active, yes.
Circuit 2
Metric 0
2
1000Mb
If active, yes.
Circuit 3
Metric 1
1
500Mb
Only when circuit 1
fails.
Circuit 4
Metric 1
2
1000Mb
Only when circuit 2
fails.
TABLE 73
Tunnel with one failover groups with three circuits
Circuits in tunnel
Failover group ID
Circuit bandwidth
In use for tunnel data
Circuit 1
Metric 0
1
1000Mb
If active, yes.
Circuit 2
Metric 1
1
500Mb
Only when circuit 1
fails.
Circuit 3
Metric 1
1
500Mb
Only when circuit 1
fails.
Summary of Contents for Network Advisor 12.3.0
Page 4: ...iv Brocade Network Advisor SAN User Manual 53 1003154 01...
Page 86: ...34 Brocade Network Advisor SAN User Manual 53 1003154 01 Uninstalling a patch 2...
Page 190: ...138 Brocade Network Advisor SAN User Manual 53 1003154 01 Fabric tracking 4...
Page 216: ...164 Brocade Network Advisor SAN User Manual 53 1003154 01 User profiles 5...
Page 612: ...560 Brocade Network Advisor SAN User Manual 53 1003154 01 Exporting Host port mapping 13...
Page 620: ...568 Brocade Network Advisor SAN User Manual 53 1003154 01 Exporting storage port mapping 14...
Page 720: ...668 Brocade Network Advisor SAN User Manual 53 1003154 01 Security configuration deployment 17...
Page 744: ...692 Brocade Network Advisor SAN User Manual 53 1003154 01 Configuring Virtual Fabrics 19...
Page 1068: ...1016 Brocade Network Advisor SAN User Manual 53 1003154 01 Removing thresholds 24...
Page 1098: ...1046 Brocade Network Advisor SAN User Manual 53 1003154 01 Swapping blades 25...
Page 1176: ...1124 Brocade Network Advisor SAN User Manual 53 1003154 01 SAN connection utilization 28...
Page 1378: ...1326 Brocade Network Advisor SAN User Manual 53 1003154 01 Event logs 32...
Page 1448: ...1396 Brocade Network Advisor SAN User Manual 53 1003154 01 Upload failure data capture 34...
Page 1490: ...1438 Brocade Network Advisor SAN User Manual 53 1003154 01 SAN shortcut menus A...
Page 1494: ...1442 Brocade Network Advisor SAN User Manual 53 1003154 01 Call Home Event Tables B...
Page 1524: ...1472 Brocade Network Advisor SAN User Manual 53 1003154 01 About Roles and Access Levels D...
Page 1552: ...1500 Brocade Network Advisor SAN User Manual 53 1003154 01 Regular Expressions F...
Page 1920: ...1868 Brocade Network Advisor SAN User Manual 53 1003154 01 Views H...