Connecting cascaded FICON fabrics over FCIP
22
Compression mode
More aggressive compression modes can be used for asynchronous mirroring. For synchronous
mirroring, only hardware or standard compression should be used. This is because more
aggressive algorithms work by receiving additional frames to find compressible patterns on larger
blocks of data. The time it takes to read in these additional frames add latency, which may not be
tolerated by synchronous mirroring. Set compression modes on the Add FCIP Tunnel dialog box.
Circuit Keep Alive Time Out values
The circuit Keep Alive Time Out value, located on the Transmission tab of FCIP Circuit Advanced
Settings dialog box, should be less than the protocol timeout for the application being extended.
This allows circuit failover to be non-disruptive. By default, the circuit keep alive is 10 seconds
(10000 ms) and 1 second (1000 ms) for FICON. Set this to 6 seconds (6000 ms) for IBM
peer-to-peer remote copy (PPRC). All other applications should use the default.
SRDF considerations
Use SRDF/S SiRT (Single Roundtrip) or SRDF/A with FCIP-FW but not both.
Using SRDF/A and
SRDF/S on the same remote adapter (RA) ports on the array is not recommended.
Use different
VE_Ports for the tunnels, as if the tunnel destinations are different. If there is only one destination
(SRDF/A and SRDF/S are going to the same place), isolate traffic from the SRDF/A and SRDF/S RA
ports using TI zones and configure the tunnels accordingly. Note that there may be differences in
bandwidth, Fast Write, and compression mode tunnel parameters.
EMC
MirrorView
CLARiiON
Sync
Yes
EMC
SANcopy
CLARiiON
Async
Yes
HDS
Universal Replicator
(HUR)
All
Async
No
HDS
TrueCopy
All
Async
No
HP
Continuous Access
EVA
Hybrid
No
*
OSTP
Tape
Tape
Yes (required for OSTP)
TABLE 77
Using Fast Write for extended applications
Manufacturer
RDR Application
Platform
Type
Use Fast Write
Summary of Contents for Network Advisor 12.3.0
Page 4: ...iv Brocade Network Advisor SAN User Manual 53 1003154 01...
Page 86: ...34 Brocade Network Advisor SAN User Manual 53 1003154 01 Uninstalling a patch 2...
Page 190: ...138 Brocade Network Advisor SAN User Manual 53 1003154 01 Fabric tracking 4...
Page 216: ...164 Brocade Network Advisor SAN User Manual 53 1003154 01 User profiles 5...
Page 612: ...560 Brocade Network Advisor SAN User Manual 53 1003154 01 Exporting Host port mapping 13...
Page 620: ...568 Brocade Network Advisor SAN User Manual 53 1003154 01 Exporting storage port mapping 14...
Page 720: ...668 Brocade Network Advisor SAN User Manual 53 1003154 01 Security configuration deployment 17...
Page 744: ...692 Brocade Network Advisor SAN User Manual 53 1003154 01 Configuring Virtual Fabrics 19...
Page 1068: ...1016 Brocade Network Advisor SAN User Manual 53 1003154 01 Removing thresholds 24...
Page 1098: ...1046 Brocade Network Advisor SAN User Manual 53 1003154 01 Swapping blades 25...
Page 1176: ...1124 Brocade Network Advisor SAN User Manual 53 1003154 01 SAN connection utilization 28...
Page 1378: ...1326 Brocade Network Advisor SAN User Manual 53 1003154 01 Event logs 32...
Page 1448: ...1396 Brocade Network Advisor SAN User Manual 53 1003154 01 Upload failure data capture 34...
Page 1490: ...1438 Brocade Network Advisor SAN User Manual 53 1003154 01 SAN shortcut menus A...
Page 1494: ...1442 Brocade Network Advisor SAN User Manual 53 1003154 01 Call Home Event Tables B...
Page 1524: ...1472 Brocade Network Advisor SAN User Manual 53 1003154 01 About Roles and Access Levels D...
Page 1552: ...1500 Brocade Network Advisor SAN User Manual 53 1003154 01 Regular Expressions F...
Page 1920: ...1868 Brocade Network Advisor SAN User Manual 53 1003154 01 Views H...