Brocade Network Advisor SAN User Manual
1447
53-1003154-01
Product events
C
Product events
All other events originating from the product are categorized as product events.
IP Performance monitoring events
IP performance monitoring events, listed in
Table 130
, occur when users select the option to
forward events to the vCenter during VM Manager discovery.
RASLog Events
The supported events for Event Triggered backup are listed in
Table 131
.
TABLE 130
Performance monitoring IP threshold events
Trap name
OID
Description
bnaRisingThresholdCrossed
1.3.6.1.4.1.1991.1.13.2.0.1
The value of monitored SNMP
variable or expression has exceeded
the value specified as the higher
threshold.
bnaFallingThresholdCrossed
1.3.6.1.4.1.1991.1.13.2.0.1
The value of the monitored SNMP
variable or expression has failed
below the value specified as the
lower threshold.
TABLE 131
Configuration change events
Event ID
Type
Description
AG-1006
LOG
Access Gateway mode has been enabled or disabled.
AG-1013
LOG
N_port failover.
AG-1014
LOG
N_port failback.
AG-1016
LOG
Failing over F_Ports mapped to N_Port <
port number
> to other N_Ports.
AG-1020
LOG
F_Ports to N_Ports route mapping has been changed.
AG-1022
LOG
F_Port <
f_port
> is failed over to its preferred N_Port <
n_port
>.
AG-1023
LOG
F_Port <
f_port
> mapped to offline N_Port <
n_port
> is failed over to its
preferred N_Port <
preferred port
>.
AG-1033
AUDIT | LOG
F_Port to N_Port mapping has been updated for N_Port (<
n_port
>).
AG-1041
LOG
Static F_Ports mapped to N_Port <
port number
> are disabled as Trunking
is enabled on the N_Port.
AN-1006
AUDIT
Bottleneck detection configuration is successfully changed.
AN-1006
AUDIT
Bottleneck detection configuration is successfully changed.
BL-1001
LOG
Port initialization completed.
BLS-1002
AUDIT | LOG
An IPsec/IKE policy was added.
BLS-1003
AUDIT | LOG
An IPsec/IKE policy was deleted.
CONF-1000
LOG | AUDIT
configDownload completed successfully.
Summary of Contents for Network Advisor 12.3.0
Page 4: ...iv Brocade Network Advisor SAN User Manual 53 1003154 01...
Page 86: ...34 Brocade Network Advisor SAN User Manual 53 1003154 01 Uninstalling a patch 2...
Page 190: ...138 Brocade Network Advisor SAN User Manual 53 1003154 01 Fabric tracking 4...
Page 216: ...164 Brocade Network Advisor SAN User Manual 53 1003154 01 User profiles 5...
Page 612: ...560 Brocade Network Advisor SAN User Manual 53 1003154 01 Exporting Host port mapping 13...
Page 620: ...568 Brocade Network Advisor SAN User Manual 53 1003154 01 Exporting storage port mapping 14...
Page 720: ...668 Brocade Network Advisor SAN User Manual 53 1003154 01 Security configuration deployment 17...
Page 744: ...692 Brocade Network Advisor SAN User Manual 53 1003154 01 Configuring Virtual Fabrics 19...
Page 1068: ...1016 Brocade Network Advisor SAN User Manual 53 1003154 01 Removing thresholds 24...
Page 1098: ...1046 Brocade Network Advisor SAN User Manual 53 1003154 01 Swapping blades 25...
Page 1176: ...1124 Brocade Network Advisor SAN User Manual 53 1003154 01 SAN connection utilization 28...
Page 1378: ...1326 Brocade Network Advisor SAN User Manual 53 1003154 01 Event logs 32...
Page 1448: ...1396 Brocade Network Advisor SAN User Manual 53 1003154 01 Upload failure data capture 34...
Page 1490: ...1438 Brocade Network Advisor SAN User Manual 53 1003154 01 SAN shortcut menus A...
Page 1494: ...1442 Brocade Network Advisor SAN User Manual 53 1003154 01 Call Home Event Tables B...
Page 1524: ...1472 Brocade Network Advisor SAN User Manual 53 1003154 01 About Roles and Access Levels D...
Page 1552: ...1500 Brocade Network Advisor SAN User Manual 53 1003154 01 Regular Expressions F...
Page 1920: ...1868 Brocade Network Advisor SAN User Manual 53 1003154 01 Views H...